Adaptive threshold segmentation of pituitary adenomas from FDG PET images for radiosurgery. (8th November 2014)
- Record Type:
- Journal Article
- Title:
- Adaptive threshold segmentation of pituitary adenomas from FDG PET images for radiosurgery. (8th November 2014)
- Main Title:
- Adaptive threshold segmentation of pituitary adenomas from FDG PET images for radiosurgery
- Authors:
- Thomas T, Hannah M.
Devadhas, Devakumar
Heck, Danie K.
Chacko, Ari G.
Rebekah, Grace
Oommen, Regi
Samuel, E. James J. - Abstract:
- Abstract : In this study we have attempted to optimize a PET based adaptive threshold segmentation method for delineating small tumors, particularly in a background of high tracer activity. The metabolic nature of pituitary adenomas and the constraints of MRI imaging in the postoperative setting to delineate these tumors during radiosurgical procedures motivated us to develop this method. Phantom experiments were done to establish a relationship between the threshold required for segmenting the PET images and the target size and the activity concentration within the target in relation to its background. The threshold was developed from multiple linear regression of the experimental data optimized for tumor sizes less than 4 cm 3 . We validated our method against the phantom target volumes with measured target to background ratios ranging from 1.6 to 14.58. The method was tested on ten retrospective patients with residual growth hormone‐secreting pituitary adenomas that underwent radiosurgery and compared against the volumes delineated by manual method. The predicted volumes against the true volume of the phantom inserts gave a correlation coefficient of 99% ( p < 0.01 ) . In the ten retrospective patients, the automatically segmented tumor volumes against volumes manually delineated by the clinicians had a correlation of 94% ( p < 0.01 ) . This adaptive threshold segmentation showed promising results in delineating tumor volumes in pituitary adenomas planned for stereotacticAbstract : In this study we have attempted to optimize a PET based adaptive threshold segmentation method for delineating small tumors, particularly in a background of high tracer activity. The metabolic nature of pituitary adenomas and the constraints of MRI imaging in the postoperative setting to delineate these tumors during radiosurgical procedures motivated us to develop this method. Phantom experiments were done to establish a relationship between the threshold required for segmenting the PET images and the target size and the activity concentration within the target in relation to its background. The threshold was developed from multiple linear regression of the experimental data optimized for tumor sizes less than 4 cm 3 . We validated our method against the phantom target volumes with measured target to background ratios ranging from 1.6 to 14.58. The method was tested on ten retrospective patients with residual growth hormone‐secreting pituitary adenomas that underwent radiosurgery and compared against the volumes delineated by manual method. The predicted volumes against the true volume of the phantom inserts gave a correlation coefficient of 99% ( p < 0.01 ) . In the ten retrospective patients, the automatically segmented tumor volumes against volumes manually delineated by the clinicians had a correlation of 94% ( p < 0.01 ) . This adaptive threshold segmentation showed promising results in delineating tumor volumes in pituitary adenomas planned for stereotactic radiosurgery, particularly in the postoperative setting where MR and CT images may be associated with artifacts, provided optimization experiment is carried out. PACS number: 87.57.nm, 87.57.uk … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 15:Number 6(2014)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 15:Number 6(2014)
- Issue Display:
- Volume 15, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 6
- Issue Sort Value:
- 2014-0015-0006-0000
- Page Start:
- 279
- Page End:
- 294
- Publication Date:
- 2014-11-08
- Subjects:
- pituitary adenoma -- adaptive threshold -- segmentation -- positron emission tomography
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v15i6.4952 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 344.xml