Equivalent‐quality unflattened photon beam modeling, planning, and delivery. (8th July 2013)
- Record Type:
- Journal Article
- Title:
- Equivalent‐quality unflattened photon beam modeling, planning, and delivery. (8th July 2013)
- Main Title:
- Equivalent‐quality unflattened photon beam modeling, planning, and delivery
- Authors:
- Huang, Yunfei
Flynn, Ryan T.
Alfredo, R.
Siochi, C.
Bayouth, John E. - Abstract:
- Abstract : The clinical application of the flattening filter‐free photon beam (FFF) has enjoyed greater use due to its advantage of reduced treatment time because of the increased dose rate. Its unique beam characteristics, along with the very high‐dose rate, require a thorough knowledge of the capability and accuracy in FFF beam modeling, planning, and delivery. This work verifies the feasibility of modeling an equivalent quality unflattened photon beam (eqUF), and the dosimetric accuracy in eqUF beam planning and delivery. An eqUF beam with a beam quality equivalent to a conventional 6 MV photon beam with the filter in place (WF) was modeled for the Pinnacle 3 TPS and the beam model quality was evaluated by gamma index test. Results showed that the eqUF beam modeling was similar to that of the WF beam, as the overall passing rate of the 2 % / 2 mm gamma index test was 99.5% in the eqUF beam model and 96% in the WF beam model. Hypofractionated IMRT plans were then generated with the same constraints using both WF and eqUF beams, and the similarity was evaluated by DVH comparison and generalized 3D gamma index test. The WF and eqUF plans showed no clinically significant differences in DVH comparison and, on average > 98 % voxels passed the 3 % / 3 mm 3D gamma index test. Dosimetric accuracy in gated phantom delivery was verified by ion chamber and film measurements. All ion chamber measurements at the isocenter were within 1% of calculated values and film measurements passedAbstract : The clinical application of the flattening filter‐free photon beam (FFF) has enjoyed greater use due to its advantage of reduced treatment time because of the increased dose rate. Its unique beam characteristics, along with the very high‐dose rate, require a thorough knowledge of the capability and accuracy in FFF beam modeling, planning, and delivery. This work verifies the feasibility of modeling an equivalent quality unflattened photon beam (eqUF), and the dosimetric accuracy in eqUF beam planning and delivery. An eqUF beam with a beam quality equivalent to a conventional 6 MV photon beam with the filter in place (WF) was modeled for the Pinnacle 3 TPS and the beam model quality was evaluated by gamma index test. Results showed that the eqUF beam modeling was similar to that of the WF beam, as the overall passing rate of the 2 % / 2 mm gamma index test was 99.5% in the eqUF beam model and 96% in the WF beam model. Hypofractionated IMRT plans were then generated with the same constraints using both WF and eqUF beams, and the similarity was evaluated by DVH comparison and generalized 3D gamma index test. The WF and eqUF plans showed no clinically significant differences in DVH comparison and, on average > 98 % voxels passed the 3 % / 3 mm 3D gamma index test. Dosimetric accuracy in gated phantom delivery was verified by ion chamber and film measurements. All ion chamber measurements at the isocenter were within 1% of calculated values and film measurements passed the 3 mm / 3 % gamma index test with an overall passing rate > 95 % in the high‐dose and low‐gradient region in both WF and eqUF cases. Treatment plan quality assurance (QA), using either measurement‐based or independent calculation‐based methods of ten clinically treated eqUF IMRT plans were analyzed. In both methods, the point dose differences were all within 2% difference. In the relative 2D dose distribution comparison, > 95 % points were within 3% dose difference or 3 mm DTA. PACS number: 87.55.kh … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 14:Number 4(2013)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 14:Number 4(2013)
- Issue Display:
- Volume 14, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 14
- Issue:
- 4
- Issue Sort Value:
- 2013-0014-0004-0000
- Page Start:
- 108
- Page End:
- 120
- Publication Date:
- 2013-07-08
- Subjects:
- flattening filter free -- unflattened photon beam -- FFF beam modeling -- FFF beam planning
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v14i4.4211 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2541.xml