Cone‐beam computed tomography image guided therapy to evaluate lumpectomy cavity variation before and during breast radiotherapy. (4th March 2013)
- Record Type:
- Journal Article
- Title:
- Cone‐beam computed tomography image guided therapy to evaluate lumpectomy cavity variation before and during breast radiotherapy. (4th March 2013)
- Main Title:
- Cone‐beam computed tomography image guided therapy to evaluate lumpectomy cavity variation before and during breast radiotherapy
- Authors:
- Truong, Minh Tam
Hirsch, Ariel E.
Kovalchuk, Nataliya
Qureshi, Muhammad M.
Damato, Antonio
Schuller, Bradley
Vassilakis, Nectaria
Stone, Michael
Gierga, David
Willins, John
Kachnic, Lisa A. - Abstract:
- Abstract : The purpose of this study was to evaluate the rate of change (RoC) in the size of the lumpectomy cavity (LC) before and during breast radiotherapy (RT) using cone‐beam computed tomography (CBCT), relative to the initial LC volume at CT simulation ( CTV LC ) and timing from surgery. A prospective institutional review board‐approved study included 26 patients undergoing breast RT: 20 whole breast irradiation (WBI) patients and six partial breast irradiation (PBI) patients, with surgical clips outlining the LC. The patients underwent CT simulation ( CT sim ) followed by five CBCTs during RT, once daily for PBI and once weekly for WBI. The distance between surgical clips and their centroid (D) acted as a surrogate for LC size. The RoC of the LC size, defined as the percentage change of D between two scans divided by the time interval in days between the scans, was calculated before ( CT sim to CBCT1) and during RT (CBCT1 to CBCT5). The mean RoC of D for all patients before starting RT was − 0.25 % / day (range, − 1.3 to 1.4) and for WBI patients during RT was − 0.15 % / day (range, − 0.45 to 0.40). Stratified by median CTV LC, the RoC before RT for large CTV LC group ( ≥ 25.7 cc ) was 15 times higher ( − 0.47 % / day ) than for small CTV LC group ( < 25.7 cc) ( − 0.03 % / day ), p = 0.06 . For patients undergoing CT sim < 42 days from surgery, the RoC before RT was − 0.43 % / day compared to − 0.07 % / day for patients undergoing CT sim ≥ 42 days from surgery, p =Abstract : The purpose of this study was to evaluate the rate of change (RoC) in the size of the lumpectomy cavity (LC) before and during breast radiotherapy (RT) using cone‐beam computed tomography (CBCT), relative to the initial LC volume at CT simulation ( CTV LC ) and timing from surgery. A prospective institutional review board‐approved study included 26 patients undergoing breast RT: 20 whole breast irradiation (WBI) patients and six partial breast irradiation (PBI) patients, with surgical clips outlining the LC. The patients underwent CT simulation ( CT sim ) followed by five CBCTs during RT, once daily for PBI and once weekly for WBI. The distance between surgical clips and their centroid (D) acted as a surrogate for LC size. The RoC of the LC size, defined as the percentage change of D between two scans divided by the time interval in days between the scans, was calculated before ( CT sim to CBCT1) and during RT (CBCT1 to CBCT5). The mean RoC of D for all patients before starting RT was − 0.25 % / day (range, − 1.3 to 1.4) and for WBI patients during RT was − 0.15 % / day (range, − 0.45 to 0.40). Stratified by median CTV LC, the RoC before RT for large CTV LC group ( ≥ 25.7 cc ) was 15 times higher ( − 0.47 % / day ) than for small CTV LC group ( < 25.7 cc) ( − 0.03 % / day ), p = 0.06 . For patients undergoing CT sim < 42 days from surgery, the RoC before RT was − 0.43 % / day compared to − 0.07 % / day for patients undergoing CT sim ≥ 42 days from surgery, p = 0.12 . For breast cancer RT, the rate of change of the LC is affected by the initial cavity size and the timing from surgery. Resimulation closer to the time of boost treatment should be considered in patients who are initially simulated within six weeks of surgery and/or with large CTV LC . PACS number: 87.55.de … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 14:Number 2(2013)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 14:Number 2(2013)
- Issue Display:
- Volume 14, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 14
- Issue:
- 2
- Issue Sort Value:
- 2013-0014-0002-0000
- Page Start:
- 209
- Page End:
- 219
- Publication Date:
- 2013-03-04
- Subjects:
- breast radiotherapy -- seroma -- lumpectomy cavity -- surgical clips -- cone‐beam computed tomography
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v14i2.4243 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1186.xml