A dosimetric evaluation of VMAT for the treatment of non‐small cell lung cancer. (1st September 2012)
- Record Type:
- Journal Article
- Title:
- A dosimetric evaluation of VMAT for the treatment of non‐small cell lung cancer. (1st September 2012)
- Main Title:
- A dosimetric evaluation of VMAT for the treatment of non‐small cell lung cancer
- Authors:
- Merrow, Caitlin E.
Wang, Iris Z.
Podgorsak, Matthew B. - Abstract:
- Abstract : The purpose of this study was to demonstrate the dosimetric potential of volumetric‐modulated arc therapy (VMAT) for the treatment of patients with medically inoperable stage I/II non‐small cell lung cancer (NSCLC) with stereotactic body radiation therapy (SBRT). Fourteen patients treated with 3D CRT with varying tumor locations, tumor sizes, and dose fractionation schemes were chosen for study. The prescription doses were 48 Gy in 4 fractions, 52.5 Gy in 5 fractions, 57.5 Gy in 5 fractions, and 60 Gy in 3 fractions for 2, 5, 1, and 6 patients, respectively. VMAT treatment plans with a mix of two to three full and partial noncoplanar arcs with 5°–25° separations were retrospectively generated using Eclipse version 10.0. The 3D CRT and VMAT plans were then evaluated by comparing their target dose, critical structure dose, high dose spillage, and low dose spillage as defined according to RTOG 0813 and RTOG 0236 protocols. In the most dosimetrically improved case, VMAT was able to decrease the dose from 17.35 Gy to 1.54 Gy to the heart. The D 2 cm decreased in 11 of 14 cases when using VMAT. The three that worsened were still within the acceptance criteria. Of the 14 3D CRT plans, seven had a D 2 cm minor deviation, while only one of the 14 VMAT plans had a D 2 cm minor deviation. The R 50 % improved in 13 of the 14 VMAT cases. The one case that worsened was still within the acceptance criteria of the RTOG protocol. Of the 14 3D CRT plans, seven had an R 50 %Abstract : The purpose of this study was to demonstrate the dosimetric potential of volumetric‐modulated arc therapy (VMAT) for the treatment of patients with medically inoperable stage I/II non‐small cell lung cancer (NSCLC) with stereotactic body radiation therapy (SBRT). Fourteen patients treated with 3D CRT with varying tumor locations, tumor sizes, and dose fractionation schemes were chosen for study. The prescription doses were 48 Gy in 4 fractions, 52.5 Gy in 5 fractions, 57.5 Gy in 5 fractions, and 60 Gy in 3 fractions for 2, 5, 1, and 6 patients, respectively. VMAT treatment plans with a mix of two to three full and partial noncoplanar arcs with 5°–25° separations were retrospectively generated using Eclipse version 10.0. The 3D CRT and VMAT plans were then evaluated by comparing their target dose, critical structure dose, high dose spillage, and low dose spillage as defined according to RTOG 0813 and RTOG 0236 protocols. In the most dosimetrically improved case, VMAT was able to decrease the dose from 17.35 Gy to 1.54 Gy to the heart. The D 2 cm decreased in 11 of 14 cases when using VMAT. The three that worsened were still within the acceptance criteria. Of the 14 3D CRT plans, seven had a D 2 cm minor deviation, while only one of the 14 VMAT plans had a D 2 cm minor deviation. The R 50 % improved in 13 of the 14 VMAT cases. The one case that worsened was still within the acceptance criteria of the RTOG protocol. Of the 14 3D CRT plans, seven had an R 50 % deviation. Only one of the 14 VMAT plans had an R 50 % deviation, but it was still improved compared to the 3D CRT plan. In this cohort of patients, no evident dosimetric compromises resulted from planning SBRT treatments with VMAT relative to the 3D CRT treatment plans actually used in their treatment. PACS numbers: 87.50.‐a, 87.53.‐j, 87.55.‐x, 87.55.D‐, 87.55.dk, 87.55.de … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 14:Number 1(2013)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 14:Number 1(2013)
- Issue Display:
- Volume 14, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 14
- Issue:
- 1
- Issue Sort Value:
- 2013-0014-0001-0000
- Page Start:
- 228
- Page End:
- 238
- Publication Date:
- 2012-09-01
- Subjects:
- volumetric‐modulated arc therapy (VMAT) -- stereotactic body radiation therapy (SBRT) -- three‐dimensional conformal radiation therapy (3D CRT) -- non‐small cell lung cancer (NSCLC)
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v14i1.4110 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 67.xml