Multi-directional mechanical analysis of synthetic scaffolds for hernia repair. (July 2017)
- Record Type:
- Journal Article
- Title:
- Multi-directional mechanical analysis of synthetic scaffolds for hernia repair. (July 2017)
- Main Title:
- Multi-directional mechanical analysis of synthetic scaffolds for hernia repair
- Authors:
- Est, Savannah
Roen, Madeleine
Chi, Tingying
Simien, Adrian
Castile, Ryan M.
Thompson, Dominic M.
Blatnik, Jeffrey A.
Deeken, Corey R.
Lake, Spencer P. - Abstract:
- Abstract: Hernias remain one of the most common ailments to affect men and women worldwide. Surgical mesh materials were first used to reinforce hernia defects during surgery in the late 1950s (Laker, n.d.). Today, there are well over 50 prosthetic meshes available for hernia repair (Brown and Finch, 2010; Bryan et al., 2014; Hope and El-hayek, 2014). With the multitude of available options, surgeons are faced with the challenging task of optimizing mesh selection for each patient. If the mechanics of the mesh are not compatible with the surrounding tissue, mismatch can occur, which can lead to complications such as mesh failure and/or hernia recurrence. Unfortunately, many aspects of synthetic mesh mechanics remain poorly described. Therefore, the purpose of this study was to provide a more complete mechanical analysis of a variety of commercially available prosthetic meshes for hernia repair, including evaluation of meshes in a variety of orientations. Twenty different meshes were subjected to biaxial tensile tests at both 90° and 45° orientations, and results were analyzed for relative strength, strain behavior, and anisotropy. Peak tension and strain values varied dramatically across all mesh types for all directions, ranging between 4.08 and 25.74 N/cm and −5% to 10% strain. Anisotropy ratios for the evaluated meshes ranged from 0.33 to 1.89, demonstrating a wide range in relative direction-dependence of mesh mechanics. While further study of prosthetic meshes andAbstract: Hernias remain one of the most common ailments to affect men and women worldwide. Surgical mesh materials were first used to reinforce hernia defects during surgery in the late 1950s (Laker, n.d.). Today, there are well over 50 prosthetic meshes available for hernia repair (Brown and Finch, 2010; Bryan et al., 2014; Hope and El-hayek, 2014). With the multitude of available options, surgeons are faced with the challenging task of optimizing mesh selection for each patient. If the mechanics of the mesh are not compatible with the surrounding tissue, mismatch can occur, which can lead to complications such as mesh failure and/or hernia recurrence. Unfortunately, many aspects of synthetic mesh mechanics remain poorly described. Therefore, the purpose of this study was to provide a more complete mechanical analysis of a variety of commercially available prosthetic meshes for hernia repair, including evaluation of meshes in a variety of orientations. Twenty different meshes were subjected to biaxial tensile tests at both 90° and 45° orientations, and results were analyzed for relative strength, strain behavior, and anisotropy. Peak tension and strain values varied dramatically across all mesh types for all directions, ranging between 4.08 and 25.74 N/cm and −5% to 10% strain. Anisotropy ratios for the evaluated meshes ranged from 0.33 to 1.89, demonstrating a wide range in relative direction-dependence of mesh mechanics. While further study of prosthetic meshes and better characterization of properties of the human abdominal wall are needed, results of this study provide valuable data that may aid clinicians in optimizing mesh selection for specific patients and repair conditions. Highlights: Twenty different hernia meshes were mechanically tested at varying orientations. Meshes were biaxially tested for anisotropy, tension, strain, and secant modulus. Mesh orientation changes resulted in variations of mechanical properties. More data are needed to determine the best mechanical fit for hernia mesh repair. Graphical abstract: … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 71(2017)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 71(2017)
- Issue Display:
- Volume 71, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 71
- Issue:
- 2017
- Issue Sort Value:
- 2017-0071-2017-0000
- Page Start:
- 43
- Page End:
- 53
- Publication Date:
- 2017-07
- Subjects:
- Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2017.02.009 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2004.xml