Typhoon- and temperature-induced quasi-static responses of a supertall structure. (15th July 2017)
- Record Type:
- Journal Article
- Title:
- Typhoon- and temperature-induced quasi-static responses of a supertall structure. (15th July 2017)
- Main Title:
- Typhoon- and temperature-induced quasi-static responses of a supertall structure
- Authors:
- Su, J.Z.
Xia, Y.
Zhu, L.D.
Zhu, H.P.
Ni, Y.Q. - Abstract:
- Highlights: Temperature- and wind-induced quasi-static responses are separated and compared. Canton Tower is investigated using a comprehensive real-time structural monitoring system. Measured typhoon-induced displacement is compared with the results of the wind tunnel test. Abstract: Wind loads and the associated load effects on supertall structures are key factors in structural design. In practice, typhoon-induced quasi-static responses measured from the field mix with temperature-induced responses because temperature varies significantly during a typhoon event. The mixed responses complicate the assessment of the wind loading effects and the separation of the two load effects is difficult in practice. In this study, the wind- and temperature-induced quasi-static responses of the 600 m-tall Canton Tower are investigated using a comprehensive long-term structural monitoring system installed on the structure. The structural responses (stresses and displacement) obtained from the field monitoring system during a strong typhoon are presented. The temperature-induced responses are calculated by applying a temperature loading model to the finite element model of the structure. The purely typhoon-induced quasi-static responses are then separated from the total measured responses by subtracting the temperature-induced ones. It shows that the typhoon-induced quasi-static responses of the supertall structure are slightly smaller than the temperature-induced responses in a typicalHighlights: Temperature- and wind-induced quasi-static responses are separated and compared. Canton Tower is investigated using a comprehensive real-time structural monitoring system. Measured typhoon-induced displacement is compared with the results of the wind tunnel test. Abstract: Wind loads and the associated load effects on supertall structures are key factors in structural design. In practice, typhoon-induced quasi-static responses measured from the field mix with temperature-induced responses because temperature varies significantly during a typhoon event. The mixed responses complicate the assessment of the wind loading effects and the separation of the two load effects is difficult in practice. In this study, the wind- and temperature-induced quasi-static responses of the 600 m-tall Canton Tower are investigated using a comprehensive long-term structural monitoring system installed on the structure. The structural responses (stresses and displacement) obtained from the field monitoring system during a strong typhoon are presented. The temperature-induced responses are calculated by applying a temperature loading model to the finite element model of the structure. The purely typhoon-induced quasi-static responses are then separated from the total measured responses by subtracting the temperature-induced ones. It shows that the typhoon-induced quasi-static responses of the supertall structure are slightly smaller than the temperature-induced responses in a typical sunny day. The typhoon-induced quasi-static displacement obtained from the field is also compared with the counterpart from the wind tunnel test on an aeroelastic model of the full tower. … (more)
- Is Part Of:
- Engineering structures. Volume 143(2017:Jul. 15)
- Journal:
- Engineering structures
- Issue:
- Volume 143(2017:Jul. 15)
- Issue Display:
- Volume 143 (2017)
- Year:
- 2017
- Volume:
- 143
- Issue Sort Value:
- 2017-0143-0000-0000
- Page Start:
- 91
- Page End:
- 100
- Publication Date:
- 2017-07-15
- Subjects:
- Supertall structure -- Temperature effect -- Wind effect -- Field monitoring -- Quasi-static response
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2017.04.007 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 725.xml