Defluoridation of drinking water using a new flow column-electrocoagulation reactor (FCER) - Experimental, statistical, and economic approach. (15th July 2017)
- Record Type:
- Journal Article
- Title:
- Defluoridation of drinking water using a new flow column-electrocoagulation reactor (FCER) - Experimental, statistical, and economic approach. (15th July 2017)
- Main Title:
- Defluoridation of drinking water using a new flow column-electrocoagulation reactor (FCER) - Experimental, statistical, and economic approach
- Authors:
- Hashim, Khalid S.
Shaw, Andy
Al Khaddar, Rafid
Ortoneda Pedrola, Montserrat
Phipps, David - Abstract:
- Abstract: A new batch, flow column electrocoagulation reactor (FCER) that utilises a perforated plate flow column as a mixer has been used to remove fluoride from drinking water. A comprehensive study has been carried out to assess its performance. The efficiency of fluoride removal (R%) as a function of key operational parameters such as initial pH, detention time (t), current density (CD), inter-electrode distance (ID) and initial concentration (C0 ) has been examined and an empirical model has been developed. A scanning electron microscopy (SEM) investigation of the influence of the EC process on morphology of the surface of the aluminium electrodes, showed the erosion caused by aluminium loss. A preliminary estimation of the reactor's operating cost is suggested, allowing for the energy from recycling of hydrogen gas hydrogen gas produced amount. The results obtained showed that 98% of fluoride was removed within 25 min of electrolysis at pH of 6, ID of 5 mm, and CD of 2 mA/cm 2 . The general relationship between fluoride removal and operating parameters could be described by a linear model with R 2 of 0.823. The contribution of the operating parameters to the suggested model followed the order: t > CD > C0 > ID > pH. The SEM images obtained showed that, after the EC process, the surface of the anodes, became non-uniform with a large number of irregularities due to the generation of aluminium hydroxides. It is suggested that these do not materially affect theAbstract: A new batch, flow column electrocoagulation reactor (FCER) that utilises a perforated plate flow column as a mixer has been used to remove fluoride from drinking water. A comprehensive study has been carried out to assess its performance. The efficiency of fluoride removal (R%) as a function of key operational parameters such as initial pH, detention time (t), current density (CD), inter-electrode distance (ID) and initial concentration (C0 ) has been examined and an empirical model has been developed. A scanning electron microscopy (SEM) investigation of the influence of the EC process on morphology of the surface of the aluminium electrodes, showed the erosion caused by aluminium loss. A preliminary estimation of the reactor's operating cost is suggested, allowing for the energy from recycling of hydrogen gas hydrogen gas produced amount. The results obtained showed that 98% of fluoride was removed within 25 min of electrolysis at pH of 6, ID of 5 mm, and CD of 2 mA/cm 2 . The general relationship between fluoride removal and operating parameters could be described by a linear model with R 2 of 0.823. The contribution of the operating parameters to the suggested model followed the order: t > CD > C0 > ID > pH. The SEM images obtained showed that, after the EC process, the surface of the anodes, became non-uniform with a large number of irregularities due to the generation of aluminium hydroxides. It is suggested that these do not materially affect the performance. A provisional estimate of the operating cost was 0.379 US $/m 3 . Additionally, it has been found that 0.6 kW/m 3 is potentially recoverable from the H2 gas. Graphical abstract: Fluoride removal at different initial concentrations. Highlights: The new reactor, FCER, removed 98% of fluoride. Performance of FECR, in terms of fluoride removal, was modelled with R 2 of 0.823. FCER emits H2 gas enough to produce energy of 0.6 kW/m 3 . SEM images showed many dents on the anode due to the production of Al hydroxides. FCER required 0.379 US $/m 3 to remove 20 mg/L of fluoride from drinking water. … (more)
- Is Part Of:
- Journal of environmental management. Volume 197(2017)
- Journal:
- Journal of environmental management
- Issue:
- Volume 197(2017)
- Issue Display:
- Volume 197, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 197
- Issue:
- 2017
- Issue Sort Value:
- 2017-0197-2017-0000
- Page Start:
- 80
- Page End:
- 88
- Publication Date:
- 2017-07-15
- Subjects:
- Fluoride -- Electrocoagulation -- Perforated electrodes -- Modelling -- SEM -- Operating cost
Environmental policy -- Periodicals
Environmental management -- Periodicals
Environment -- Periodicals
Ecology -- Periodicals
363.705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03014797 ↗
http://www.elsevier.com/journals ↗
http://www.idealibrary.com ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1016/j.jenvman.2017.03.048 ↗
- Languages:
- English
- ISSNs:
- 0301-4797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4979.383000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1509.xml