Experimental characterisation of a micro Humid Air Turbine: assessment of the thermodynamic performance. (25th May 2017)
- Record Type:
- Journal Article
- Title:
- Experimental characterisation of a micro Humid Air Turbine: assessment of the thermodynamic performance. (25th May 2017)
- Main Title:
- Experimental characterisation of a micro Humid Air Turbine: assessment of the thermodynamic performance
- Authors:
- Montero Carrero, Marina
De Paepe, Ward
Magnusson, Jan
Parente, Alessandro
Bram, Svend
Contino, Francesco - Abstract:
- Highlights: A T100 micro gas turbine has been converted into a micro humid air turbine. To do so, a unique spray saturation tower was designed and built for the facility. We have conducted experiments at constant power and constant rotational speed. Experimental results show an electrical efficiency increase of 4.2 percentage pt. Abstract: Despite appearing as a promising technology for distributed generation, micro Gas Turbines (mGTs) have not yet managed to penetrate the small-scale Combined Heat and Power (CHP) market. The energy efficiency of mGTs amounts to 80% whenever both heat and electricity are required. However, when the heat demand is low, the hot exhaust gases have to be directly blown off and the electrical efficiency of the unit ( ∼ 30 % ) is not high enough to sustain profitable operation. Water injection, achieved when transforming the mGT into a micro Humid Air Turbine (mHAT), allows making use of the exhaust gas heat in such cases, thus increasing electrical efficiency of the technology and improving its feasibility. Although the enhanced performance of the mHAT cycle has been thoroughly investigated from a numerical point of view, results regarding the experimental behaviour of this technology remain scarce. In this paper, we present the experimental characterisation of the mHAT located at Vrije Universiteit Brussel (VUB) which is based on the T100 mGT equipped with a spray saturation tower. These are the first experimental results of such an engineHighlights: A T100 micro gas turbine has been converted into a micro humid air turbine. To do so, a unique spray saturation tower was designed and built for the facility. We have conducted experiments at constant power and constant rotational speed. Experimental results show an electrical efficiency increase of 4.2 percentage pt. Abstract: Despite appearing as a promising technology for distributed generation, micro Gas Turbines (mGTs) have not yet managed to penetrate the small-scale Combined Heat and Power (CHP) market. The energy efficiency of mGTs amounts to 80% whenever both heat and electricity are required. However, when the heat demand is low, the hot exhaust gases have to be directly blown off and the electrical efficiency of the unit ( ∼ 30 % ) is not high enough to sustain profitable operation. Water injection, achieved when transforming the mGT into a micro Humid Air Turbine (mHAT), allows making use of the exhaust gas heat in such cases, thus increasing electrical efficiency of the technology and improving its feasibility. Although the enhanced performance of the mHAT cycle has been thoroughly investigated from a numerical point of view, results regarding the experimental behaviour of this technology remain scarce. In this paper, we present the experimental characterisation of the mHAT located at Vrije Universiteit Brussel (VUB) which is based on the T100 mGT equipped with a spray saturation tower. These are the first experimental results of such an engine working at nominal load with water injection. In addition, the control system of the unit has been modified so that it can operate either at constant electrical power output (the default setting) or at constant rotational speed. The latter option allowed better assessing the effect of water injection. Experimental results demonstrate the patent benefits of water injection on mGT performance: at fixed rotational speed, the power output of the mHAT increases by more than 30% while fuel consumption rises only by 11%. Overall, the electrical efficiency in wet operation increases by up to 4.2% absolute points. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 118(2017)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 118(2017)
- Issue Display:
- Volume 118, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 118
- Issue:
- 2017
- Issue Sort Value:
- 2017-0118-2017-0000
- Page Start:
- 796
- Page End:
- 806
- Publication Date:
- 2017-05-25
- Subjects:
- Distributed generation -- Micro gas turbine -- Micro humid air turbine -- experimental characterisation
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2017.03.017 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1685.xml