Is the instrumented-pointer method of calibrating anatomical landmarks in 3D motion analysis reliable?. (28th February 2017)
- Record Type:
- Journal Article
- Title:
- Is the instrumented-pointer method of calibrating anatomical landmarks in 3D motion analysis reliable?. (28th February 2017)
- Main Title:
- Is the instrumented-pointer method of calibrating anatomical landmarks in 3D motion analysis reliable?
- Authors:
- Tawy, Gwenllian Fflur
Rowe, Philip - Abstract:
- Abstract: Instrumented-pointers are often used to calibrate anatomical landmarks in biomechanical analyses. However, little is known about the effect of altering the orientation of the pointer during calibration on the co-ordinates recorded. Incorrect positioning of a landmark influences the axes created, and thus the kinematic data recorded. This study aimed to investigate the reliability of the pointer method for anatomical calibration. Two points were drawn onto a fixed box to resemble knee joint epicondyles, then a custom-made pointer was used to define the positions of these landmarks in three-dimensions. Twenty different pointer-orientations were chosen, and the position of the pointer in each of these orientations was recorded 8 times. Euclidean distances between single points were calculated for both landmarks and compared statistically ( α = 0.05). Average Euclidean distances between all reconstructed points were 3.2±1.4 mm (range: 0.3–7.1 mm) for one landmark and 3.3±1.5 mm (range: 0.3–7.9mm) for the other. The x - and y -co-ordinates recorded differed statistically when the pointer was moved about the X and Y axes (anterior/posterior and superior/inferior to landmark) ( p < 0.05). No statistical differences were found between co-ordinates recorded when the pointer was moved around the Z axes ( p > 0.05). ICC values for all co-ordinates were excellent, highlighting the reliability of the method (ICC > 0.90). These results support this method of anatomicalAbstract: Instrumented-pointers are often used to calibrate anatomical landmarks in biomechanical analyses. However, little is known about the effect of altering the orientation of the pointer during calibration on the co-ordinates recorded. Incorrect positioning of a landmark influences the axes created, and thus the kinematic data recorded. This study aimed to investigate the reliability of the pointer method for anatomical calibration. Two points were drawn onto a fixed box to resemble knee joint epicondyles, then a custom-made pointer was used to define the positions of these landmarks in three-dimensions. Twenty different pointer-orientations were chosen, and the position of the pointer in each of these orientations was recorded 8 times. Euclidean distances between single points were calculated for both landmarks and compared statistically ( α = 0.05). Average Euclidean distances between all reconstructed points were 3.2±1.4 mm (range: 0.3–7.1 mm) for one landmark and 3.3±1.5 mm (range: 0.3–7.9mm) for the other. The x - and y -co-ordinates recorded differed statistically when the pointer was moved about the X and Y axes (anterior/posterior and superior/inferior to landmark) ( p < 0.05). No statistical differences were found between co-ordinates recorded when the pointer was moved around the Z axes ( p > 0.05). ICC values for all co-ordinates were excellent, highlighting the reliability of the method (ICC > 0.90). These results support this method of anatomical calibration; however, we recommend that pointers be consistently held in a neutral oriented position (where the handle is not anterior, posterior, superior or inferior to the landmark) during calibration, to reduce the likelihood of calibration errors. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 53(2017)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 53(2017)
- Issue Display:
- Volume 53, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 53
- Issue:
- 2017
- Issue Sort Value:
- 2017-0053-2017-0000
- Page Start:
- 205
- Page End:
- 209
- Publication Date:
- 2017-02-28
- Subjects:
- Motion analysis -- Anatomical landmark calibration -- Subject calibration -- Protocol reliability -- instrumented-pointer
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2017.01.019 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1611.xml