Impact of Contact Force Technology on Atrial Fibrillation Ablation: A Meta‐Analysis. Issue 9 (September 2015)
- Record Type:
- Journal Article
- Title:
- Impact of Contact Force Technology on Atrial Fibrillation Ablation: A Meta‐Analysis. Issue 9 (September 2015)
- Main Title:
- Impact of Contact Force Technology on Atrial Fibrillation Ablation: A Meta‐Analysis
- Authors:
- Shurrab, Mohammed
Di Biase, Luigi
Briceno, David F.
Kaoutskaia, Anna
Haj‐Yahia, Saleem
Newman, David
Lashevsky, Ilan
Nakagawa, Hiroshi
Crystal, Eugene - Abstract:
- Abstract : Background: Catheter–tissue contact is essential for effective lesion formation, thus there is growing usage of contact force (CF) technology in atrial fibrillation ablation. We conducted a meta‐analysis to assess the impact of CF on clinical outcomes and procedural parameters in comparison to conventional catheter for atrial fibrillation ablation. Methods and Results: An electronic search was performed using major databases. Outcomes of interest were recurrence rate, major complications, total procedure, and fluoroscopic times. Continuous variables were reported as standardized mean difference; odds ratios were reported for dichotomous variables. Eleven studies (2 randomized controlled studies and 9 cohorts) involving 1428 adult patients were identified. CF was deployed in 552 patients. The range of CF used was between 2 to 60 gram‐force. The follow‐up period ranged between 10 and 53 weeks. In comparing CF and conventional catheter groups, the recurrence rate was lower with CF (35.1% versus 45.5%, odds ratio 0.62 [95% CI 0.45–0.86], P =0.004). Shorter procedure and fluoroscopic times were achieved with CF (procedure time: 156 versus 173 minutes, standardized mean difference −0.85 [95% CI −1.48 to −0.21], P =0.009; fluoroscopic time: 28 versus 36 minutes, standardized mean difference −0.94 [95% CI −1.66; −0.21], P =0.01). Major complication rate was lower numerically in the CF group but not statistically significant (1.3% versus 1.9%, odds ratio 0.71 [95% CIAbstract : Background: Catheter–tissue contact is essential for effective lesion formation, thus there is growing usage of contact force (CF) technology in atrial fibrillation ablation. We conducted a meta‐analysis to assess the impact of CF on clinical outcomes and procedural parameters in comparison to conventional catheter for atrial fibrillation ablation. Methods and Results: An electronic search was performed using major databases. Outcomes of interest were recurrence rate, major complications, total procedure, and fluoroscopic times. Continuous variables were reported as standardized mean difference; odds ratios were reported for dichotomous variables. Eleven studies (2 randomized controlled studies and 9 cohorts) involving 1428 adult patients were identified. CF was deployed in 552 patients. The range of CF used was between 2 to 60 gram‐force. The follow‐up period ranged between 10 and 53 weeks. In comparing CF and conventional catheter groups, the recurrence rate was lower with CF (35.1% versus 45.5%, odds ratio 0.62 [95% CI 0.45–0.86], P =0.004). Shorter procedure and fluoroscopic times were achieved with CF (procedure time: 156 versus 173 minutes, standardized mean difference −0.85 [95% CI −1.48 to −0.21], P =0.009; fluoroscopic time: 28 versus 36 minutes, standardized mean difference −0.94 [95% CI −1.66; −0.21], P =0.01). Major complication rate was lower numerically in the CF group but not statistically significant (1.3% versus 1.9%, odds ratio 0.71 [95% CI 0.29–1.73], P =0.45). Conclusions: The use of CF technology results in significant reduction of the atrial fibrillation recurrence rate after atrial fibrillation ablation in comparison to the conventional catheter group. CF technology is able to significantly reduce procedure and fluoroscopic times without compromising complication rate. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 4:Issue 9(2015)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 4:Issue 9(2015)
- Issue Display:
- Volume 4, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 4
- Issue:
- 9
- Issue Sort Value:
- 2015-0004-0009-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2015-09
- Subjects:
- ablation -- atrial fibrillation -- contact force -- meta‐analysis
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.115.002476 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2168.xml