Talar dome detection and its geometric approximation in CT: Sphere, cylinder or bi-truncated cone?. (April 2017)
- Record Type:
- Journal Article
- Title:
- Talar dome detection and its geometric approximation in CT: Sphere, cylinder or bi-truncated cone?. (April 2017)
- Main Title:
- Talar dome detection and its geometric approximation in CT: Sphere, cylinder or bi-truncated cone?
- Authors:
- Huang, Junbin
Liu, He
Wang, Defeng
Griffith, James F.
Shi, Lin - Abstract:
- Highlights: We proposed a novel method for talar dome surface separation. Both curvature and distance information were considered in talar dome definition. The similarity between talar dome and bi-truncated cone is most prominent. Abstract: Objective: The purpose of our study is to give a relatively objective definition of talar dome and its shape approximations to sphere (SPH), cylinder (CLD) and bi-truncated cone (BTC). Materials and methods: The "talar dome" is well-defined with the improved Dijkstra's algorithm, considering the Euclidean distance and surface curvature. The geometric similarity between talar dome and ideal shapes, namely SPH, CLD and BTC, is quantified. 50 unilateral CT datasets from 50 subjects with no pathological morphometry of tali were included in the experiments and statistical analyses were carried out based on the approximation error. Results: The similarity between talar dome and BTC was more prominent, with smaller mean, standard deviation, maximum and median of the approximation error (0.36 ± 0.07 mm, 0.32 ± 0.06 mm, 2.24 ± 0.47 mm and 0.28 ± 0.06 mm) compare with fitting to SPH and CLD. In addition, there were significant differences between the fitting error of each pair of models in terms of the 4 measurements ( p -values < 0.05). The linear regression analyses demonstrated high correlation between CLD and BTC approximations (R 2 = 0.55 for median, R 2 > 0.7 for others). Color maps representing fitting error indicated that fitting errorHighlights: We proposed a novel method for talar dome surface separation. Both curvature and distance information were considered in talar dome definition. The similarity between talar dome and bi-truncated cone is most prominent. Abstract: Objective: The purpose of our study is to give a relatively objective definition of talar dome and its shape approximations to sphere (SPH), cylinder (CLD) and bi-truncated cone (BTC). Materials and methods: The "talar dome" is well-defined with the improved Dijkstra's algorithm, considering the Euclidean distance and surface curvature. The geometric similarity between talar dome and ideal shapes, namely SPH, CLD and BTC, is quantified. 50 unilateral CT datasets from 50 subjects with no pathological morphometry of tali were included in the experiments and statistical analyses were carried out based on the approximation error. Results: The similarity between talar dome and BTC was more prominent, with smaller mean, standard deviation, maximum and median of the approximation error (0.36 ± 0.07 mm, 0.32 ± 0.06 mm, 2.24 ± 0.47 mm and 0.28 ± 0.06 mm) compare with fitting to SPH and CLD. In addition, there were significant differences between the fitting error of each pair of models in terms of the 4 measurements ( p -values < 0.05). The linear regression analyses demonstrated high correlation between CLD and BTC approximations (R 2 = 0.55 for median, R 2 > 0.7 for others). Color maps representing fitting error indicated that fitting error mainly occurred on the marginal regions of talar dome for SPH and CLD fittings, while that of BTC was small for the whole talar dome. Conclusion: The successful restoration of ankle functions in displacement surgery highly depends on the comprehensive understanding of the talus. The talar dome surface could be well-defined in a computational way and compared to SPH and CLD, the talar dome reflects outstanding similarity with BTC. … (more)
- Is Part Of:
- Computerized medical imaging and graphics. Volume 57(2017)
- Journal:
- Computerized medical imaging and graphics
- Issue:
- Volume 57(2017)
- Issue Display:
- Volume 57, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 57
- Issue:
- 2017
- Issue Sort Value:
- 2017-0057-2017-0000
- Page Start:
- 62
- Page End:
- 66
- Publication Date:
- 2017-04
- Subjects:
- Computed tomography -- Talar dome -- Shape quantification -- Least-square
Diagnostic imaging -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnosis, Radioscopic -- Data processing -- Periodicals
Diagnostic Imaging -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Diagnostic imaging
Periodicals
Electronic journals
Electronic journals
616.0754 - Journal URLs:
- http://www.journals.elsevier.com/computerized-medical-imaging-and-graphics/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compmedimag.2016.06.002 ↗
- Languages:
- English
- ISSNs:
- 0895-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.586000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 207.xml