Analytical comparison between two hematological analyzer systems: CAL‐8000 vs. XN‐9000. (4th November 2016)
- Record Type:
- Journal Article
- Title:
- Analytical comparison between two hematological analyzer systems: CAL‐8000 vs. XN‐9000. (4th November 2016)
- Main Title:
- Analytical comparison between two hematological analyzer systems: CAL‐8000 vs. XN‐9000
- Authors:
- Buoro, S.
Mecca, T.
Seghezzi, M.
Manenti, B.
Azzarà, G.
Dominoni, P.
Crippa, A.
Ottomano, C.
Lippi, G. - Abstract:
- Summary: Introduction: This study was aimed to compare the analytical performance of traditional and new parameters and morphological flags of CAL‐8000 and XN‐9000. The automated differential leukocyte count (DIFF profile) and morphological flags were compared with optical microscopy (OM). Methods: A total of 1025 peripheral blood samples, collected in K3 EDTA tubes, were analyzed by CAL‐8000, by XN‐9000, and by OM. Within‐run imprecision was performed in low cellularity samples. The comparison was made using Spearman's correlation, Passing–Bablok regression, Bland–Altman bias, and Cohen's K test. Results: Within‐run imprecision in low cellularity samples yielded reproducible data between the instruments (imprecision was higher than 10% on samples with platelet count <21 × 10 9 /L using impedance technology). Passing–Bablok regression (CAL‐8000 vs . XN‐9000) yielded slopes ranging between 0.2 to 1.16 and intercepts from −6.54 to 21.63. The bias for leukocytes parameters ranged from −1.8% to −82.2%, the red blood cell parameters from −2.9% to 3.1%, platelets parameters from −27.8% to 26%, and reticulocyte parameters from −115.3% to 4.5%. The comparison of morphological flags yielded a K value always <0.55. The DIFF profile vs . OM had a Passing–Bablok regression with slopes ranging between 0.34 to 1.00 and intercepts from −0.01% to 0.11 and bias ranging from −42.9% to 2.6% for XN‐9000 parameters and from −2.7% to 35.0% for CAL‐8000 parameters. The comparison of morphologicalSummary: Introduction: This study was aimed to compare the analytical performance of traditional and new parameters and morphological flags of CAL‐8000 and XN‐9000. The automated differential leukocyte count (DIFF profile) and morphological flags were compared with optical microscopy (OM). Methods: A total of 1025 peripheral blood samples, collected in K3 EDTA tubes, were analyzed by CAL‐8000, by XN‐9000, and by OM. Within‐run imprecision was performed in low cellularity samples. The comparison was made using Spearman's correlation, Passing–Bablok regression, Bland–Altman bias, and Cohen's K test. Results: Within‐run imprecision in low cellularity samples yielded reproducible data between the instruments (imprecision was higher than 10% on samples with platelet count <21 × 10 9 /L using impedance technology). Passing–Bablok regression (CAL‐8000 vs . XN‐9000) yielded slopes ranging between 0.2 to 1.16 and intercepts from −6.54 to 21.63. The bias for leukocytes parameters ranged from −1.8% to −82.2%, the red blood cell parameters from −2.9% to 3.1%, platelets parameters from −27.8% to 26%, and reticulocyte parameters from −115.3% to 4.5%. The comparison of morphological flags yielded a K value always <0.55. The DIFF profile vs . OM had a Passing–Bablok regression with slopes ranging between 0.34 to 1.00 and intercepts from −0.01% to 0.11 and bias ranging from −42.9% to 2.6% for XN‐9000 parameters and from −2.7% to 35.0% for CAL‐8000 parameters. The comparison of morphological flags showed a K value ranging from 0.35 to 0.77 for XN‐9000 and from 0.17 to 0.54 for CAL‐8000. Conclusion: Differences exist between the two analyzers, especially in the generation of morphology flags, thus emphasizing the need of pursuing a major degree of harmonization and/or adopting instrument‐specific reference ranges. … (more)
- Is Part Of:
- International journal of laboratory hematology. Volume 39:Number 2(2017:Apr.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 39:Number 2(2017:Apr.)
- Issue Display:
- Volume 39, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 39
- Issue:
- 2
- Issue Sort Value:
- 2017-0039-0002-0000
- Page Start:
- 147
- Page End:
- 162
- Publication Date:
- 2016-11-04
- Subjects:
- XN‐9000 -- CAL‐8000 -- automated count -- optical microscopy -- mindray -- sysmex
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.12597 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1018.xml