Respiratory rate estimation from the photoplethysmogram via joint sparse signal reconstruction and spectra fusion. (May 2017)
- Record Type:
- Journal Article
- Title:
- Respiratory rate estimation from the photoplethysmogram via joint sparse signal reconstruction and spectra fusion. (May 2017)
- Main Title:
- Respiratory rate estimation from the photoplethysmogram via joint sparse signal reconstruction and spectra fusion
- Authors:
- Zhang, Xiaorong
Ding, Quan - Abstract:
- Highlights: Joint sparse signal reconstruction is used to estimate respiratory rate from the PPG. Two methods are proposed to fuse the sparse spectra to estimate respiratory rate. The algorithms have been tested on a public benchmark database CapnoBase. The algorithms works well with a low sampling frequency of 10 Hz. Abstract: Respiratory rate (RR) estimation from the photoplethysmogram (PPG) is a challenging problem due to the nonstationarity of RR and disturbance. In this work, we propose a novel approach to estimate RR from the PPG signal using joint sparse signal reconstruction (JSSR) and spectra fusion (SF). A window of PPG signal is segmented into multiple overlapped measurements. Sparse spectra of these measurements are estimated by JSSR using the regularized M-FOCUSS algorithm. The kurtosis of each spectrum is used to classify it into three signal quality categories, and spectra in the highest signal quality category are fused using Respiratory Rate Tracking (RRT) to estimate RR. Validated on a public benchmark database CapnoBase, our approach outperforms a state-of-the-art algorithm in accuracy and robustness in low signal quality conditions. This is the first time JSSR has been used for RR estimation from the PPG signal. In addition, our approach works well with a low sampling frequency of 10 Hz which has great potential to be used in low-cost wearable devices.
- Is Part Of:
- Biomedical signal processing and control. Volume 35(2017)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 35(2017)
- Issue Display:
- Volume 35, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 35
- Issue:
- 2017
- Issue Sort Value:
- 2017-0035-2017-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2017-05
- Subjects:
- Photoplethysmogram -- Respiratory rate estimation -- Joint sparse signal reconstruction -- Spectra fusion
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2017.02.003 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2534.xml