Rabbit model of tracheal stenosis using cylindrical diffuser. Issue 4 (16th November 2016)
- Record Type:
- Journal Article
- Title:
- Rabbit model of tracheal stenosis using cylindrical diffuser. Issue 4 (16th November 2016)
- Main Title:
- Rabbit model of tracheal stenosis using cylindrical diffuser
- Authors:
- Lee, Hyoung Shin
Kim, Sung Won
Oak, Chulho
Kang, Hyun Wook
Oh, Junghwan
Jung, Min Jung
Kim, Sung Bin
Won, Jun Hee
Lee, Kang Dae - Abstract:
- Abstract : Background and Objective: Variable methods of animal model have been introduced to develop tracheal stenosis. However, none of the prior models allow for predictable determination of the grade of stenosis. This study sought to establish an animal model of tracheal stenosis by using a cylindrical diffuser and to evaluate the feasibility of a reproducible model. Study Design/Materials and Methods: A cylindrical diffuser was developed to have a 5 mm active segment to emit laser light circumferentially. Twenty one New Zealand white rabbits were enrolled in this study. The cylindrical diffuser was inserted transorally under bronchoscopic view and the diffused light was delivered to tracheal mucosa 2 cm below the level of vocal cord. Input power of irradiation was 10 W, 5 seconds in group A ( n = 7), 10 W, 7 seconds in group B ( n = 7), and 8 W, 5 seconds in group C ( n = 7). The degree of tracheal stenosis was observed weekly and the rabbits were euthanized 4 weeks after the laser irradiation. Results: The degree of stenosis in group B (90–98%) was significantly larger than that of group A (75–92%) ( P = 0.004), while degree in group C (24–35%) was significantly smaller than that of group A ( P < 0.001). Two rabbits of group A were euthanized at 3 weeks due to costal retraction. In group B, six rabbits died within 3 weeks after laser irradiation due to severe tracheal stenosis and tracheal malacia, while one rabbit was euthanized 16 days after the irradiation. AllAbstract : Background and Objective: Variable methods of animal model have been introduced to develop tracheal stenosis. However, none of the prior models allow for predictable determination of the grade of stenosis. This study sought to establish an animal model of tracheal stenosis by using a cylindrical diffuser and to evaluate the feasibility of a reproducible model. Study Design/Materials and Methods: A cylindrical diffuser was developed to have a 5 mm active segment to emit laser light circumferentially. Twenty one New Zealand white rabbits were enrolled in this study. The cylindrical diffuser was inserted transorally under bronchoscopic view and the diffused light was delivered to tracheal mucosa 2 cm below the level of vocal cord. Input power of irradiation was 10 W, 5 seconds in group A ( n = 7), 10 W, 7 seconds in group B ( n = 7), and 8 W, 5 seconds in group C ( n = 7). The degree of tracheal stenosis was observed weekly and the rabbits were euthanized 4 weeks after the laser irradiation. Results: The degree of stenosis in group B (90–98%) was significantly larger than that of group A (75–92%) ( P = 0.004), while degree in group C (24–35%) was significantly smaller than that of group A ( P < 0.001). Two rabbits of group A were euthanized at 3 weeks due to costal retraction. In group B, six rabbits died within 3 weeks after laser irradiation due to severe tracheal stenosis and tracheal malacia, while one rabbit was euthanized 16 days after the irradiation. All rabbits in group C survived up to 4 weeks. Survival between three groups showed significant difference ( P = 0.001). Conclusion: The degree of stenosis was significantly different according to the delivered optical energy to tracheal mucosa. Therefore, the proposed model may be used in animal studies to emulate variable grades of tracheal stenosis. Lasers Surg. Med. 49:372–379, 2017. © 2016 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Lasers in surgery and medicine. Volume 49:Issue 4(2017)
- Journal:
- Lasers in surgery and medicine
- Issue:
- Volume 49:Issue 4(2017)
- Issue Display:
- Volume 49, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 49
- Issue:
- 4
- Issue Sort Value:
- 2017-0049-0004-0000
- Page Start:
- 372
- Page End:
- 379
- Publication Date:
- 2016-11-16
- Subjects:
- animal model -- lasers -- rabbits -- tracheal stenosis
Lasers in medicine -- Periodicals
Lasers in surgery -- Periodicals
617 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/lsm.22615 ↗
- Languages:
- English
- ISSNs:
- 0196-8092
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.683000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2078.xml