Long-term viable bioaerosol sampling using a temperature- and humidity-controlled filtration apparatus, a laboratory investigation using culturable E. coli. Issue 5 (4th May 2017)
- Record Type:
- Journal Article
- Title:
- Long-term viable bioaerosol sampling using a temperature- and humidity-controlled filtration apparatus, a laboratory investigation using culturable E. coli. Issue 5 (4th May 2017)
- Main Title:
- Long-term viable bioaerosol sampling using a temperature- and humidity-controlled filtration apparatus, a laboratory investigation using culturable E. coli.
- Authors:
- Walls, Howard J.
Kim, Jean H.
Yaga, Robert W.
Harvey, Lauren A.
Haines, Laura G.
Ensor, David S.
Hering, Susanne V.
Spielman, Steven R.
Kreisberg, Nathan - Abstract:
- ABSTRACT: Sampling for culturable (e.g., viable) aerosolized microbes (bioaerosols) is a useful means to provide information for public health monitoring and studies. However, it is challenging to maintain microbe culturability when sampling at high flow rates (>12 L/min) and extended periods of time (≥4 h). We developed a first-generation, viable bioaerosol collection system (VBCS) utilizing temperature ( T ) and relative humidity (RH)–conditioned filtration at a flow rate of 25 L/min. A two-stage system of tube-in-shell Nafion™ exchange units provides cooling to ≤10°C and RH conditioning to 80–95%. Aerosol particles are collected on a polyurethane nanofiber filter providing a physical collection efficiency of >95% for sizes 0.06–10 µm. The T and RH conditions at the collection filter are maintained, despite changes to ambient conditions. The initial testing of the VBCS was done under indoor, laboratory conditions with aerosolized, vegetative E. coli . A scenario of a 30-min challenge of bioaerosol followed by continued sampling of clean air for various times was used to judge culturability maintenance under extended-term sampling. An initial loss of culturability upon collection onto the filter was observed; 23 ± 13% relative to 4-mm all-glass impinger. However once collected, 98% of culturability was maintained for an additional 4.5 h of sampling. An exponential decay in culturability was observed from 8 h to 15 h of sampling. Also, 24-h cold storage of the filtersABSTRACT: Sampling for culturable (e.g., viable) aerosolized microbes (bioaerosols) is a useful means to provide information for public health monitoring and studies. However, it is challenging to maintain microbe culturability when sampling at high flow rates (>12 L/min) and extended periods of time (≥4 h). We developed a first-generation, viable bioaerosol collection system (VBCS) utilizing temperature ( T ) and relative humidity (RH)–conditioned filtration at a flow rate of 25 L/min. A two-stage system of tube-in-shell Nafion™ exchange units provides cooling to ≤10°C and RH conditioning to 80–95%. Aerosol particles are collected on a polyurethane nanofiber filter providing a physical collection efficiency of >95% for sizes 0.06–10 µm. The T and RH conditions at the collection filter are maintained, despite changes to ambient conditions. The initial testing of the VBCS was done under indoor, laboratory conditions with aerosolized, vegetative E. coli . A scenario of a 30-min challenge of bioaerosol followed by continued sampling of clean air for various times was used to judge culturability maintenance under extended-term sampling. An initial loss of culturability upon collection onto the filter was observed; 23 ± 13% relative to 4-mm all-glass impinger. However once collected, 98% of culturability was maintained for an additional 4.5 h of sampling. An exponential decay in culturability was observed from 8 h to 15 h of sampling. Also, 24-h cold storage of the filters collected was studied. The VBCS is based on the use of dry filter cassettes, needs minimal maintenance, and preserves culturability of vegetative bacteria for >4 h. © 2017 RTI International and Aerosol Dynamics Inc. … (more)
- Is Part Of:
- Aerosol science and technology. Volume 51:Issue 5(2017)
- Journal:
- Aerosol science and technology
- Issue:
- Volume 51:Issue 5(2017)
- Issue Display:
- Volume 51, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 51
- Issue:
- 5
- Issue Sort Value:
- 2017-0051-0005-0000
- Page Start:
- 576
- Page End:
- 586
- Publication Date:
- 2017-05-04
- Subjects:
- Tiina Reponen
Aerosols -- Periodicals
Aerosol Propellants -- Periodicals
Aerosols -- Periodicals
660.294515 - Journal URLs:
- http://www.tandfonline.com/loi/uast20#.VkNQFJUnyig ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/02786826.2017.1286290 ↗
- Languages:
- English
- ISSNs:
- 0278-6826
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0729.835400
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 359.xml