Radiofrequency catheter ablation of atrioventricular node reentrant tachycardia in children with limited fluoroscopy. (1st June 2017)
- Record Type:
- Journal Article
- Title:
- Radiofrequency catheter ablation of atrioventricular node reentrant tachycardia in children with limited fluoroscopy. (1st June 2017)
- Main Title:
- Radiofrequency catheter ablation of atrioventricular node reentrant tachycardia in children with limited fluoroscopy
- Authors:
- Swissa, Moshe
Birk, Einat
Dagan, Tamir
Naimer, Sody Abby
Fogelman, Michal
Einbinder, Tom
Bruckheimer, Elchanan
Fogelman, Rami - Abstract:
- Abstract: Background: Limited fluoroscopy cryo-ablation using a 3D electro-anatomical system (3DS) has been used for AVNRT in children. We aimed to facilitate a fluoroscopy limited approach of RF ablation of AVNRT in children. Methods: A retrospective study was performed of procedure parameters in children undergoing RF ablation of AVNRT in 75 consecutive children (June 2011 to November 2013 — Group A) using standard fluoroscopy techniques compared to those of 64 consecutive children (December 2013 to May 2015 — Group B), using a fluoroscopy limited approach with 3DS. Results: The acute success rate was 98.7% (74/75) and 98.4% (63/64) for groups A and B, respectively. The recurrence rate was 2.7% (2/74) and 0% (0/63) with a mean follow-up period of 45.5 ± 12.1 and 14.3 ± 6.1 months for group A and group B, respectively. The mean procedure and fluoroscopy times were significantly lower for group B compared to group A (119 ± 37 (43–203) and 0.83 ± 1.04 (0.05–3.83) minutes versus 146 ± 53 (72–250) and 16.1 ± 8.9 (4.39–55) minutes, p < 0.003 and p < 0.0001, respectively). There were no ablation-related complications. Conclusions: A fluoroscopy limited approach for RF ablation of AVNRT in children using a 3DS is easily acquired and adapted, and significantly reduces the fluoroscopy and procedure time with excellent efficacy, safety and low recurrence rate. Condensed ABSTRACT: This study confirmed that a 3D mapping system (3DS) to guide ablations of AVNRT in children reducesAbstract: Background: Limited fluoroscopy cryo-ablation using a 3D electro-anatomical system (3DS) has been used for AVNRT in children. We aimed to facilitate a fluoroscopy limited approach of RF ablation of AVNRT in children. Methods: A retrospective study was performed of procedure parameters in children undergoing RF ablation of AVNRT in 75 consecutive children (June 2011 to November 2013 — Group A) using standard fluoroscopy techniques compared to those of 64 consecutive children (December 2013 to May 2015 — Group B), using a fluoroscopy limited approach with 3DS. Results: The acute success rate was 98.7% (74/75) and 98.4% (63/64) for groups A and B, respectively. The recurrence rate was 2.7% (2/74) and 0% (0/63) with a mean follow-up period of 45.5 ± 12.1 and 14.3 ± 6.1 months for group A and group B, respectively. The mean procedure and fluoroscopy times were significantly lower for group B compared to group A (119 ± 37 (43–203) and 0.83 ± 1.04 (0.05–3.83) minutes versus 146 ± 53 (72–250) and 16.1 ± 8.9 (4.39–55) minutes, p < 0.003 and p < 0.0001, respectively). There were no ablation-related complications. Conclusions: A fluoroscopy limited approach for RF ablation of AVNRT in children using a 3DS is easily acquired and adapted, and significantly reduces the fluoroscopy and procedure time with excellent efficacy, safety and low recurrence rate. Condensed ABSTRACT: This study confirmed that a 3D mapping system (3DS) to guide ablations of AVNRT in children reduces radiation exposure. Combined, limited fluoroscopy and 3DS in a methodology that resembles the familiar conventional fluoroscopy approach for RF ablation of AVNRT in children is proposed. Combined limited fluoroscopy and RF-energy in children with AVNRT are associated with a shorter procedure time, minimal fluoroscopy time, a high success rate and a low recurrence rate. … (more)
- Is Part Of:
- International journal of cardiology. Volume 236(2017)
- Journal:
- International journal of cardiology
- Issue:
- Volume 236(2017)
- Issue Display:
- Volume 236, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 236
- Issue:
- 2017
- Issue Sort Value:
- 2017-0236-2017-0000
- Page Start:
- 198
- Page End:
- 202
- Publication Date:
- 2017-06-01
- Subjects:
- SVT supraventricular tachycardia -- RF radiofrequency -- AVNRT atrioventricular nodal reentrant tachycardia -- 3DS 3D electro-anatomic mapping system -- AVB atrioventricular block -- RVA right ventricular apex -- HRA high right atrium -- CS coronary sinus
Catheter ablation -- Limited fluoroscopy -- Atrioventricular nodal reentrant tachycardia (AVNRT) -- Electro-anatomic mapping systems
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2017.01.128 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 674.xml