A comparison of winter indoor thermal environment and thermal comfort between regions in Europe, North America, and Asia. (15th May 2017)
- Record Type:
- Journal Article
- Title:
- A comparison of winter indoor thermal environment and thermal comfort between regions in Europe, North America, and Asia. (15th May 2017)
- Main Title:
- A comparison of winter indoor thermal environment and thermal comfort between regions in Europe, North America, and Asia
- Authors:
- Zhang, Nan
Cao, Bin
Wang, Zhaojun
Zhu, Yingxin
Lin, Borong - Abstract:
- Abstract: Along with the improvement of living quality, indoor thermal comfort has been drawing increasing attentions. In this paper, a comparison between South Europe, North America and Asia on winter indoor thermal environments, occupants' clothing insulations and their thermal sensations was conducted. The compared regions all locate in similar latitude range of temperate climate zone (northern latitude 39°54'∼53°31′). Field study data representing 10 cities chosen from ASHRAE RP-884, SCATs and China thermal comfort databases were used for the comparative study. It was observed that the indoor operative temperature and relative humidity varied from regions. European and North American cities had higher temperature while temperature of Chinese cities was the lowest. Among the three regions, indoor environments in Europe and China met well with the comfort requirements in their own regional or national standard, while North America had the highest ratio of matching the comfort zones no matter in which standard. Most of the off-comfort-zone conditions in Europe were due to overheating, contrary to those in China were mainly overcooling. Clothing insulation of Chinese was the highest and had a wider range. The winter neutral temperature for Europe, North America and China were 23.4, 22.7 and 21.7 °C respectively. A comparison between TSV and PMV was made and obvious deviation features were discovered. Europeans tend to feel colder than predicted when indoor temperature is outAbstract: Along with the improvement of living quality, indoor thermal comfort has been drawing increasing attentions. In this paper, a comparison between South Europe, North America and Asia on winter indoor thermal environments, occupants' clothing insulations and their thermal sensations was conducted. The compared regions all locate in similar latitude range of temperate climate zone (northern latitude 39°54'∼53°31′). Field study data representing 10 cities chosen from ASHRAE RP-884, SCATs and China thermal comfort databases were used for the comparative study. It was observed that the indoor operative temperature and relative humidity varied from regions. European and North American cities had higher temperature while temperature of Chinese cities was the lowest. Among the three regions, indoor environments in Europe and China met well with the comfort requirements in their own regional or national standard, while North America had the highest ratio of matching the comfort zones no matter in which standard. Most of the off-comfort-zone conditions in Europe were due to overheating, contrary to those in China were mainly overcooling. Clothing insulation of Chinese was the highest and had a wider range. The winter neutral temperature for Europe, North America and China were 23.4, 22.7 and 21.7 °C respectively. A comparison between TSV and PMV was made and obvious deviation features were discovered. Europeans tend to feel colder than predicted when indoor temperature is out of the neutral zone. Chinese TSVs were closer to neutral than they were predicted by PMV, while North Americans showed an opposite result. Highlights: A comparison between South Europe, North America and Asia on winter thermal comfort was conducted. Chinese held the lowest neutral temperature while the acceptable temperature range of North American was the narrowest. Europeans felt colder than PMV prediction in non-neutral environment. Chinese TSVs were closer to neutral than predicted by PMV while North American showed an opposite result. Indoor thermal environments in the three regions were evaluated using four different standards. … (more)
- Is Part Of:
- Building and environment. Volume 117(2017)
- Journal:
- Building and environment
- Issue:
- Volume 117(2017)
- Issue Display:
- Volume 117, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 117
- Issue:
- 2017
- Issue Sort Value:
- 2017-0117-2017-0000
- Page Start:
- 208
- Page End:
- 217
- Publication Date:
- 2017-05-15
- Subjects:
- Temperate zone -- Thermal environment -- Thermal comfort -- Clothing insulation -- Winter
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2017.03.006 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1264.xml