Osteosynthesis using cannulated headless Herbert screws in mandibular angle fracture treatment: A new approach?. Issue 4 (April 2017)
- Record Type:
- Journal Article
- Title:
- Osteosynthesis using cannulated headless Herbert screws in mandibular angle fracture treatment: A new approach?. Issue 4 (April 2017)
- Main Title:
- Osteosynthesis using cannulated headless Herbert screws in mandibular angle fracture treatment: A new approach?
- Authors:
- Wallner, Jürgen
Reinbacher, Knut
Feichtinger, Matthias
Pau, Mauro
Feigl, Georg
Quehenberger, Franz
Schwenzer-Zimmerer, Katja
Zemann, Wolfgang - Abstract:
- Abstract: Introduction: Fractures of the mandibular angle are a common type of facial skull fracture. Although operative treatment includes a wide range of fixation techniques, a definite gold standard method has yet to be established. Headless, cannulated Herbert screws, often used in many forms of minimally invasive trauma surgery, provide functional and stable fracture fixation. Materials and methods: In a prospective, double-randomised, controlled, parallel-group – designed, in vitro trial, the biomechanical behaviour of the Herbert bone screw system was compared to that of a conventional locking plate system in 40 mandibular angle fractures of human mandible cadaver phantoms. Results: The mean stress values were 250 (±68.0) N in the plate subgroup and 200 (±61.0) N in the screw subgroup. The respective mean strain values were 7.90 (±2.7) mm and 6.90 (±2.2) mm, and the respective mean stiffness were values 1.10 (±0.61) N/m and 0.78 (±0.40) N/m. The differences in the results obtained using the two treatments were not significant (p = 0.55). Conclusions: The biomechanical behaviour of the two fixation systems within the tested loads did not significantly differ with respect to postoperative parameters clinically relevant in osteosynthesis. Both systems met the mandibular angle assessment criterion, which is considered to be sufficient for clinical use. The results indicate the potential clinical utility of these two systems, and recommend further testing.
- Is Part Of:
- Journal of cranio-maxillofacial surgery. Volume 45:Issue 4(2017)
- Journal:
- Journal of cranio-maxillofacial surgery
- Issue:
- Volume 45:Issue 4(2017)
- Issue Display:
- Volume 45, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 4
- Issue Sort Value:
- 2017-0045-0004-0000
- Page Start:
- 526
- Page End:
- 539
- Publication Date:
- 2017-04
- Subjects:
- Osteosynthesis -- Headless cannulated Herbert screw -- Mandibular angle fracture
Skull -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Maxilla -- surgery -- Periodicals
Face -- surgery -- Periodicals
Skull -- surgery -- Periodicals
Oral Surgical Procedures -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Periodicals
Surgery, Oral -- Periodicals
Electronic journals
617.514 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10105182 ↗
http://firstsearch.oclc.org ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10105182 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcms.2017.01.025 ↗
- Languages:
- English
- ISSNs:
- 1010-5182
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.482000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 279.xml