Magnetic resonance imaging of the inferior alveolar nerve with special regard to metal artifact reduction. Issue 4 (April 2017)
- Record Type:
- Journal Article
- Title:
- Magnetic resonance imaging of the inferior alveolar nerve with special regard to metal artifact reduction. Issue 4 (April 2017)
- Main Title:
- Magnetic resonance imaging of the inferior alveolar nerve with special regard to metal artifact reduction
- Authors:
- Probst, Monika
Richter, Vivien
Weitz, Jochen
Kirschke, Jan Stefan
Ganter, Carl
Troeltzsch, Matthias
Nittka, Mathias
Cornelius, Carl-Peter
Zimmer, Claus
Probst, Florian Andreas - Abstract:
- Abstract: Purpose: Magnetic resonance imaging (MRI) is an excellent imaging modality for displaying peripheral nerves. Since the knowledge about MRI of the inferior alveolar nerve (IAN) is limited, this pilot study aims to identify the prospects and limitations of MRI of the IAN, with special consideration of metal artifacts. Materials and methods: Initially, in vitro MRI of a dental implant was performed to establish an optimized protocol for metal artifact reduction using WARP sequences (a software package provided by Siemens Healthcare, Erlangen, Germany) including view angle tilting (VAT) and slice-encoding metal artifact correction (SEMAC) techniques. MRI with this optimized protocol was performed in three volunteers and four patients presenting with postoperative IAN impairment. Measuring the evaluable area and the artifact size was performed to assess the benefit of the specific artifact reduction sequences. Results: In vitro imaging of a dental implant demonstrated that WARP sequences with VAT and SEMAC techniques led to a volume reduction of the artifact of up to 69.1%. Observations in both volunteers and patients with neurosensory IAN impairment showed a distinct artifact reduction with the MRI protocol adapted to metallic materials. Additionally VAT and SEMAC techniques improved the imaging due to further artifact reduction. As a main drawback of the VAT technique, the image quality was compromised by a blurring effect. Still, on 3-T MRI the resolution was highAbstract: Purpose: Magnetic resonance imaging (MRI) is an excellent imaging modality for displaying peripheral nerves. Since the knowledge about MRI of the inferior alveolar nerve (IAN) is limited, this pilot study aims to identify the prospects and limitations of MRI of the IAN, with special consideration of metal artifacts. Materials and methods: Initially, in vitro MRI of a dental implant was performed to establish an optimized protocol for metal artifact reduction using WARP sequences (a software package provided by Siemens Healthcare, Erlangen, Germany) including view angle tilting (VAT) and slice-encoding metal artifact correction (SEMAC) techniques. MRI with this optimized protocol was performed in three volunteers and four patients presenting with postoperative IAN impairment. Measuring the evaluable area and the artifact size was performed to assess the benefit of the specific artifact reduction sequences. Results: In vitro imaging of a dental implant demonstrated that WARP sequences with VAT and SEMAC techniques led to a volume reduction of the artifact of up to 69.1%. Observations in both volunteers and patients with neurosensory IAN impairment showed a distinct artifact reduction with the MRI protocol adapted to metallic materials. Additionally VAT and SEMAC techniques improved the imaging due to further artifact reduction. As a main drawback of the VAT technique, the image quality was compromised by a blurring effect. Still, on 3-T MRI the resolution was high enough to reveal even fine structures. Imaging of the IAN was successful in all cases despite metallic material in the region of interest, and structural IAN changes could be detected in correlation with clinical symptoms. Conclusion: In contrast to conventional radiography and computed tomography, MRI can directly depict the IAN and provide reliable information on its position and exact course within the mandible. MRI offers an objective assessment of IAN injuries, supporting the decision-making process regarding surgical exploration and microneural repair. With the advent of specialized MRI techniques such as VAT and SEMAC, reduction of metal artifacts is considerably improved. … (more)
- Is Part Of:
- Journal of cranio-maxillofacial surgery. Volume 45:Issue 4(2017)
- Journal:
- Journal of cranio-maxillofacial surgery
- Issue:
- Volume 45:Issue 4(2017)
- Issue Display:
- Volume 45, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 4
- Issue Sort Value:
- 2017-0045-0004-0000
- Page Start:
- 558
- Page End:
- 569
- Publication Date:
- 2017-04
- Subjects:
- MRI -- Inferior alveolar nerve -- Metal artifact reduction -- SEMAC -- View-angle tilting -- VAT
Skull -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Maxilla -- surgery -- Periodicals
Face -- surgery -- Periodicals
Skull -- surgery -- Periodicals
Oral Surgical Procedures -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Periodicals
Surgery, Oral -- Periodicals
Electronic journals
617.514 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10105182 ↗
http://firstsearch.oclc.org ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10105182 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcms.2017.01.009 ↗
- Languages:
- English
- ISSNs:
- 1010-5182
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.482000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 279.xml