Long-term prognosis and cost-effectiveness of left ventricular assist device as bridge to transplantation: A systematic review. (15th May 2017)
- Record Type:
- Journal Article
- Title:
- Long-term prognosis and cost-effectiveness of left ventricular assist device as bridge to transplantation: A systematic review. (15th May 2017)
- Main Title:
- Long-term prognosis and cost-effectiveness of left ventricular assist device as bridge to transplantation: A systematic review
- Authors:
- Seco, Michael
Zhao, Dong Fang
Byrom, Michael J.
Wilson, Michael K.
Vallely, Michael P.
Fraser, John F.
Bannon, Paul G. - Abstract:
- Abstract: Background: This systematic review aimed to evaluate the clinical outcomes and cost-effectiveness of left ventricular assist devices (LVADs) used as bridge to transplantation (BTT), compared to orthotopic heart transplantation (OHT) without a bridge. Method: Systematic searches were performed in electronic databases with available data extracted from text and digitized figures. Meta-analysis of short and long-term term post-transplantation outcomes was performed with summation of cost-effectiveness analyses. Results: Twenty studies reported clinical outcomes of 4575 patients (1083 LVAD BTT and 3492 OHT). Five studies reported cost-effectiveness data on 837 patients (339 VAD BTT and 498 OHT). There was no difference in long-term post-transplantation survival (HR 1.24, 95% CI 1.00–1.54), acute rejection (HR 1.10, 95% CI 0.93–1.30), or chronic rejection and cardiac allograft vasculopathy (HR 0.99, 95% CI 0.73–1.36). No differences were found in 30-day post-operative mortality (OR 0.91, 95% CI 0.42–2.00), stroke (OR 1.64, 95% CI 0.43–6.27), renal failure (OR 1.43, 95% CI 0.58–3.54), bleeding (OR 1.56, 95% CI 0.78–3.13), or infection (OR 2.44, 95% CI 0.81–7.38). Three of the five studies demonstrated incremental cost-effectiveness ratios below the acceptable maximum threshold. The total cost of VAD BTT ranged from $316, 078 to $1, 025, 500, and OHT ranged from $179, 051 to $802, 200. Conclusion: LVADs used as BTT did not significantly alter post-transplantationAbstract: Background: This systematic review aimed to evaluate the clinical outcomes and cost-effectiveness of left ventricular assist devices (LVADs) used as bridge to transplantation (BTT), compared to orthotopic heart transplantation (OHT) without a bridge. Method: Systematic searches were performed in electronic databases with available data extracted from text and digitized figures. Meta-analysis of short and long-term term post-transplantation outcomes was performed with summation of cost-effectiveness analyses. Results: Twenty studies reported clinical outcomes of 4575 patients (1083 LVAD BTT and 3492 OHT). Five studies reported cost-effectiveness data on 837 patients (339 VAD BTT and 498 OHT). There was no difference in long-term post-transplantation survival (HR 1.24, 95% CI 1.00–1.54), acute rejection (HR 1.10, 95% CI 0.93–1.30), or chronic rejection and cardiac allograft vasculopathy (HR 0.99, 95% CI 0.73–1.36). No differences were found in 30-day post-operative mortality (OR 0.91, 95% CI 0.42–2.00), stroke (OR 1.64, 95% CI 0.43–6.27), renal failure (OR 1.43, 95% CI 0.58–3.54), bleeding (OR 1.56, 95% CI 0.78–3.13), or infection (OR 2.44, 95% CI 0.81–7.38). Three of the five studies demonstrated incremental cost-effectiveness ratios below the acceptable maximum threshold. The total cost of VAD BTT ranged from $316, 078 to $1, 025, 500, and OHT ranged from $179, 051 to $802, 200. Conclusion: LVADs used as BTT did not significantly alter post-transplantation long-term survival, rejection, and post-operative morbidity. LVAD BTT may be cost-effective, particularly in medium and high-risk patients with expected prolonged waiting times, renal dysfunction, and young patients. … (more)
- Is Part Of:
- International journal of cardiology. Volume 235(2017)
- Journal:
- International journal of cardiology
- Issue:
- Volume 235(2017)
- Issue Display:
- Volume 235, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 235
- Issue:
- 2017
- Issue Sort Value:
- 2017-0235-2017-0000
- Page Start:
- 22
- Page End:
- 32
- Publication Date:
- 2017-05-15
- Subjects:
- Left ventricular assist device -- Bridge-to-transplantation -- Heart transplantation -- Systematic review -- Meta-analysis
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2017.02.137 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2376.xml