Treating patients with Dynamic Wave Arc: First clinical experience. Issue 3 (March 2017)
- Record Type:
- Journal Article
- Title:
- Treating patients with Dynamic Wave Arc: First clinical experience. Issue 3 (March 2017)
- Main Title:
- Treating patients with Dynamic Wave Arc: First clinical experience
- Authors:
- Burghelea, Manuela
Verellen, Dirk
Dhont, Jennifer
Hung, Cecilia
Gevaert, Thierry
Van den Begin, Robbe
Collen, Christine
Poels, Kenneth
Tournel, Koen
Boussaer, Marlies
Jaudet, Cyril
Reynders, Truus
Simon, Viorica
de Ridder, Mark - Abstract:
- Abstract: Background and purpose: Dynamic Wave Arc (DWA) is a system-specific noncoplanar arc technique that combines synchronized gantry-ring rotation with D-MLC optimization. This paper presents the clinical workflow, quality assurance program, and reports the geometric and dosimetric results of the first patient cohort treated with DWA. Methods and materials: The RayStation TPS was clinically integrated on the Vero SBRT platform for DWA treatments. The first 15 patients treated with DWA represent a broad range of treatment sites: breast boost, prostate, lung SBRT and bone metastases, which allowed us to explore the potentials and assess the limitations of the current DWA site-specific template solution. For the DWA verification a variety of QA equipment was used, from 3D diode array to an anthropomorphic end-to-end phantom. The geometric accuracy of each arc was verified with an independent orthogonal fluoroscopy method. Results: The average beam-on delivery time was 3 min, ranging from 1.22 min to 8.82 min. All patient QAs passed our institutional clinical criteria of gamma index. For both EBT3 film and Delta4 measurements, DWA planned versus delivered dose distributions presented an average agreement above 97%. An overall mean gantry-ring geometric deviation of −0.03° ± 0.46° and 0.18° ± 0.26° was obtained, respectively. Conclusion: For the first time, DWA has been translated into the clinic and used to treat various treatment sides. DWA has been successfully added toAbstract: Background and purpose: Dynamic Wave Arc (DWA) is a system-specific noncoplanar arc technique that combines synchronized gantry-ring rotation with D-MLC optimization. This paper presents the clinical workflow, quality assurance program, and reports the geometric and dosimetric results of the first patient cohort treated with DWA. Methods and materials: The RayStation TPS was clinically integrated on the Vero SBRT platform for DWA treatments. The first 15 patients treated with DWA represent a broad range of treatment sites: breast boost, prostate, lung SBRT and bone metastases, which allowed us to explore the potentials and assess the limitations of the current DWA site-specific template solution. For the DWA verification a variety of QA equipment was used, from 3D diode array to an anthropomorphic end-to-end phantom. The geometric accuracy of each arc was verified with an independent orthogonal fluoroscopy method. Results: The average beam-on delivery time was 3 min, ranging from 1.22 min to 8.82 min. All patient QAs passed our institutional clinical criteria of gamma index. For both EBT3 film and Delta4 measurements, DWA planned versus delivered dose distributions presented an average agreement above 97%. An overall mean gantry-ring geometric deviation of −0.03° ± 0.46° and 0.18° ± 0.26° was obtained, respectively. Conclusion: For the first time, DWA has been translated into the clinic and used to treat various treatment sides. DWA has been successfully added to the noncoplanar rotational IMRT techniques arsenal, allowing additional flexibility in dose shaping while preserving dosimetrically robust delivery. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 122:Issue 3(2017:Mar.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 122:Issue 3(2017:Mar.)
- Issue Display:
- Volume 122, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 122
- Issue:
- 3
- Issue Sort Value:
- 2017-0122-0003-0000
- Page Start:
- 347
- Page End:
- 351
- Publication Date:
- 2017-03
- Subjects:
- Dynamic Wave Arc -- Clinical implementation -- Noncoplanar rotational IMRT
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2017.01.006 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 665.xml