Comparison of base of support size during gait initiation using force-plate and motion-capture system: A Bland and Altman analysis. Issue 16 (8th December 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of base of support size during gait initiation using force-plate and motion-capture system: A Bland and Altman analysis. Issue 16 (8th December 2016)
- Main Title:
- Comparison of base of support size during gait initiation using force-plate and motion-capture system: A Bland and Altman analysis
- Authors:
- Yiou, E.
Teyssèdre, C.
Artico, R.
Fourcade, P. - Abstract:
- Abstract: This study aimed to estimate the error made by investigators when force-plate data are used to approximate base of support size during gait initiation. Step length and step width obtained with a method based on motion capture system (Kinematics method, considered the "gold standard") and with a method based on the centre of pressure traces obtained from a force-plate (Force-plate method) were purposely compared using descriptive statistics and the Bland and Altman (BA) method. Participants ( N =19) performed series of gait initiation in Spontaneous and Maximal Velocity Conditions (SVC and MVC, respectively). BA analysis showed that 1) step length and width biases, corresponding to the difference between the two methods, were very small (<2.1%) in both velocity conditions and 2) the 95% limits of agreement of the BA plots ranged between 10% and 15% in absolute value. Repeated measures ANOVA showed that step length was significantly larger in MVC than in SVC, with no velocity X method interaction. There was no significant effect of the method on both step parameters. The present results suggest that the Force-plate method is sufficiently accurate to compare step parameters across conditions. However, researchers should be aware that non-negligible errors might occur when considering individual data.
- Is Part Of:
- Journal of biomechanics. Volume 49:Issue 16(2016)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 49:Issue 16(2016)
- Issue Display:
- Volume 49, Issue 16 (2016)
- Year:
- 2016
- Volume:
- 49
- Issue:
- 16
- Issue Sort Value:
- 2016-0049-0016-0000
- Page Start:
- 4168
- Page End:
- 4172
- Publication Date:
- 2016-12-08
- Subjects:
- Stability -- Step length/width -- Force-plate -- Motion capture -- Gait initiation
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2016.11.008 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2453.xml