Patient-specific hip geometry has greater effect on THA wear than femoral head size. Issue 16 (8th December 2016)
- Record Type:
- Journal Article
- Title:
- Patient-specific hip geometry has greater effect on THA wear than femoral head size. Issue 16 (8th December 2016)
- Main Title:
- Patient-specific hip geometry has greater effect on THA wear than femoral head size
- Authors:
- Daniel, Matej
Rijavec, Boris
Dolinar, Drago
Pokorný, David
Iglič, Aleš
Kralj-Iglič, Veronika - Abstract:
- Abstract: In vivo linear penetration in total hip arthroplasty (THA) exhibits similar values for 28 mm and 32 mm femoral head diameter with considerable variations between and within the studies. It indicates factors other than femoral head diameter influence polyethylene wear. This study is intended to test the effect of patient׳s individual geometry of musculoskeletal system, acetabular cup orientation, and radius of femoral head on wear. Variation in patient׳s musculoskeletal geometry and acetabular cup placement is evaluated in two groups of patients implanted with 28 mm and 32 mm THA heads. Linear wear rate estimated by mathematical model is 0.165–0.185 mm/year and 0.157–0.205 mm/year for 28 and 32 mm THA heads, respectively. Simulations show little influence femoral head size has on the estimated annual wear rate. Predicted annual linear wear depends mostly on the abduction angle of the acetabular cup and individual geometry of the musculoskeletal system of the hip, with the latter having the greatest affect on variation in linear wear rate.
- Is Part Of:
- Journal of biomechanics. Volume 49:Issue 16(2016)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 49:Issue 16(2016)
- Issue Display:
- Volume 49, Issue 16 (2016)
- Year:
- 2016
- Volume:
- 49
- Issue:
- 16
- Issue Sort Value:
- 2016-0049-0016-0000
- Page Start:
- 3996
- Page End:
- 4001
- Publication Date:
- 2016-12-08
- Subjects:
- UHMWPE -- Linear penetration -- Contact pressure -- Design
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2016.10.030 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2454.xml