The precision of micro-tomography in bone taphonomic experiments and the importance of registration. (April 2017)
- Record Type:
- Journal Article
- Title:
- The precision of micro-tomography in bone taphonomic experiments and the importance of registration. (April 2017)
- Main Title:
- The precision of micro-tomography in bone taphonomic experiments and the importance of registration
- Authors:
- Le Garff, Erwan
Mesli, Vadim
Delannoy, Yann
Colard, Thomas
De Jonckheere, Julien
Demondion, Xavier
Hédouin, Valéry - Abstract:
- Highlights: Micro-tomography is useful for bone architecture analyses. The precision of the device can be improved with registration. Registration is not perfect, and residual imprecision can be observed. A study about the error of precision of the device should be indicated before the use of μCT in forensic analysis. Abstract: Micro-computed tomography (μCT) provides micrometric 3D images and has been used in forensic studies for anthropology pubis measurement or insect description for post mortem interval estimation. Studies have suggested using registration, a superimposing images method between a reference and a target. This technique avoids positioning bias and increase the precision of μCT. However, no clear study has reported the precision with μCT analysis before or after registration in a forensic field. One fresh post mortem sample of a human cranial vault was collected. Two successive μCT acquisitions (resolution 10 μm) of it were performed without repositioning. The data from the second acquisition were copied and registered by two trained operators (operators 1 and 2). Operator 1 performed a second registration process after 1 week (operator 1 bis). The images were analysed. The bone volume (BV), bone surface (BS), number of trabeculae (TbN), trabecular thickness (TbTh) and mean trabecular distance (TbSp) were compared before and after registration. The mean (±SD), the coefficient of variation (%CV), and the precision error of the standard deviation absoluteHighlights: Micro-tomography is useful for bone architecture analyses. The precision of the device can be improved with registration. Registration is not perfect, and residual imprecision can be observed. A study about the error of precision of the device should be indicated before the use of μCT in forensic analysis. Abstract: Micro-computed tomography (μCT) provides micrometric 3D images and has been used in forensic studies for anthropology pubis measurement or insect description for post mortem interval estimation. Studies have suggested using registration, a superimposing images method between a reference and a target. This technique avoids positioning bias and increase the precision of μCT. However, no clear study has reported the precision with μCT analysis before or after registration in a forensic field. One fresh post mortem sample of a human cranial vault was collected. Two successive μCT acquisitions (resolution 10 μm) of it were performed without repositioning. The data from the second acquisition were copied and registered by two trained operators (operators 1 and 2). Operator 1 performed a second registration process after 1 week (operator 1 bis). The images were analysed. The bone volume (BV), bone surface (BS), number of trabeculae (TbN), trabecular thickness (TbTh) and mean trabecular distance (TbSp) were compared before and after registration. The mean (±SD), the coefficient of variation (%CV), and the precision error of the standard deviation absolute value and of the coefficient of variation between operators 1 and 2 (inter-subject variability) and between operator 1 and 1 bis (intra-subject variability) were calculated. We also collected the second phalanx of the 2nd, 3rd and 4th fingers on the hands of a second individual. Two successive scans (resolution 27 μm) were performed without repositioning. A comparison (mean ± SD of BV, BS, TbN, TbTh, TbSp) was made between the first and second scans with and without registration, and an ANOVA repeated measures procedure was performed. For the vault, we show that after 30 registrations for each operator (1, 2 and 1 bis), the mean and %CV were very close for each variable and between operators. For BV and BS, the difference in the mean value was approximately 0.01 (mm 3 and mm 2, respectively). The precision error was higher in the inter-subject registrations for each variable. The precision error magnitude for all variables was very low (<0.01) in absolute value and of %CV. For the fingers, the difference between the first and second scans may be approximately 50% without registration. We found that the second scan without registration is significantly different for BV (p = 0.006), BS (p = 0.007), TbN (p = 0.019) and TbSp (p = 0.002). Knowing the precision of the device (with and without registration) is important to ensure that the accuracy of the μCT results. … (more)
- Is Part Of:
- Forensic science international. Volume 273(2017)
- Journal:
- Forensic science international
- Issue:
- Volume 273(2017)
- Issue Display:
- Volume 273, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 273
- Issue:
- 2017
- Issue Sort Value:
- 2017-0273-2017-0000
- Page Start:
- 161
- Page End:
- 167
- Publication Date:
- 2017-04
- Subjects:
- Forensic science -- Taphonomy -- Forensic anthropology -- MicroCT -- Registration
Medical jurisprudence -- Periodicals
Chemistry, Forensic -- Periodicals
Forensic Medicine -- Periodicals
Médecine légale -- Périodiques
Chimie légale -- Périodiques
Gerechtelijke geneeskunde
Gerechtelijke chemie
Gerechtelijke psychiatrie
Chemistry, Forensic
Medical jurisprudence
Electronic journals
Periodicals
Electronic journals
614.1 - Journal URLs:
- http://www.clinicalkey.com.au/dura/browse/journalIssue/03790738 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03790738 ↗
http://www.sciencedirect.com/science/journal/03790738 ↗
http://infotrac.galegroup.com/itw/infomark/1/1/1/purl=rc18_EAIM_0__jn+%22Forensic+Science+International%22?sw_aep=stand ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.forsciint.2017.02.005 ↗
- Languages:
- English
- ISSNs:
- 0379-0738
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3987.764000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2260.xml