Influence of patient's physiologic factors and immobilization choice with stereotactic body radiotherapy for upper lung tumors. (8th September 2014)
- Record Type:
- Journal Article
- Title:
- Influence of patient's physiologic factors and immobilization choice with stereotactic body radiotherapy for upper lung tumors. (8th September 2014)
- Main Title:
- Influence of patient's physiologic factors and immobilization choice with stereotactic body radiotherapy for upper lung tumors
- Authors:
- Sio, Terence T.
Jensen, Andrew R.
Miller, Robert C.
de los Santos, Luis E. Fong
Hallemeier, Christopher L.
Foster, Nathan R.
Park, Sean S.
Bauer, Heather J.
Chang, Kenneth
Garces, Yolanda I.
Olivier, Kenneth R. - Abstract:
- Abstract : The purpose of the present study was to compare the impact of pulmonary function, body habitus, and stereotactic body radiation therapy (SBRT) immobilization on setup and reproducibility for upper lung tumor. From 2008 through 2011, our institution's prospective SBRT database was searched for patients with upper lung tumors. Two SBRT immobilization strategies were used: full‐length BodyFIX and thermoplastic S‐frame. At simulation, free‐breathing, four‐dimensional computed tomography was performed. For each treatment, patients were set up to isocenter with in‐room lasers and skin tattoos. Shifts from initial and subsequent couch positions with cone‐beam computed tomography (CBCT) were analyzed. Accounting for setup uncertainties, institutional tolerance of CBCT‐based shifts for treatment was 2, 2, and 4 mm in left–right, anterior–posterior, and cranial–caudal directions, respectively; shifts exceeding these limits required reimaging. Each patient's pretreatment pulmonary function test was recorded. A multistep, multivariate linear regression model was performed to elucidate intervariable dependency for three‐dimensional calculated couch shift parameters. BodyFIX was applied to 76 tumors and S‐frame to 17 tumors. Of these tumors, 41 were non–small cell lung cancer and 15 were metastatic from other sites. Lesions measured < 1 ( 15 % ), 1.1 to 2 (50%), 2.1 to 3 (25%), and > 3 ( 11 % ) cm. Errors from first shifts of first fractions were significantly less with S‐frameAbstract : The purpose of the present study was to compare the impact of pulmonary function, body habitus, and stereotactic body radiation therapy (SBRT) immobilization on setup and reproducibility for upper lung tumor. From 2008 through 2011, our institution's prospective SBRT database was searched for patients with upper lung tumors. Two SBRT immobilization strategies were used: full‐length BodyFIX and thermoplastic S‐frame. At simulation, free‐breathing, four‐dimensional computed tomography was performed. For each treatment, patients were set up to isocenter with in‐room lasers and skin tattoos. Shifts from initial and subsequent couch positions with cone‐beam computed tomography (CBCT) were analyzed. Accounting for setup uncertainties, institutional tolerance of CBCT‐based shifts for treatment was 2, 2, and 4 mm in left–right, anterior–posterior, and cranial–caudal directions, respectively; shifts exceeding these limits required reimaging. Each patient's pretreatment pulmonary function test was recorded. A multistep, multivariate linear regression model was performed to elucidate intervariable dependency for three‐dimensional calculated couch shift parameters. BodyFIX was applied to 76 tumors and S‐frame to 17 tumors. Of these tumors, 41 were non–small cell lung cancer and 15 were metastatic from other sites. Lesions measured < 1 ( 15 % ), 1.1 to 2 (50%), 2.1 to 3 (25%), and > 3 ( 11 % ) cm. Errors from first shifts of first fractions were significantly less with S‐frame than BodyFIX ( p < 0.001 ). No difference in local control (LC) was found between S‐frame and BodyFIX ( p = 0.35 ); two‐year LC rate was 94%. Multivariate modeling confirmed that the ratio of forced expiratory volume in the first second of expiration to forced vital capacity, body habitus, and the immobilization device significantly impacted couch shift errors. For upper lung tumors, initial setup was more consistent with S‐frame than BodyFIX, resulting in fewer CBCT scans. Patients with obese habitus and poor lung function had more SBRT setup uncertainty; however, outcome and probability for LC remained excellent. PACS number: 89.20.‐a … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 15:Number 5(2014)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 15:Number 5(2014)
- Issue Display:
- Volume 15, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 5
- Issue Sort Value:
- 2014-0015-0005-0000
- Page Start:
- 235
- Page End:
- 245
- Publication Date:
- 2014-09-08
- Subjects:
- body mass index -- immobilization -- pulmonary function test -- stereotactic body radiation therapy -- upper lung tumors
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v15i5.4931 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: