Field comparison of instruments for exposure assessment of airborne ultrafine particles and particulate matter. (April 2017)
- Record Type:
- Journal Article
- Title:
- Field comparison of instruments for exposure assessment of airborne ultrafine particles and particulate matter. (April 2017)
- Main Title:
- Field comparison of instruments for exposure assessment of airborne ultrafine particles and particulate matter
- Authors:
- Spinazzè, Andrea
Fanti, Giacomo
Borghi, Francesca
Del Buono, Luca
Campagnolo, Davide
Rovelli, Sabrina
Cattaneo, Andrea
Cavallo, Domenico M. - Abstract:
- Abstract: The objective of this study was to compare the use of co-located real-time devices and gravimetric samplers to measure ultrafine particles (UFP) and size-fractionated PM mass concentrations. The results contribute to evaluating the comparability of different monitoring instruments for size-fractionated PM concentrations. Paired light scattering devices and gravimetric samplers were used to measure the PM1, PM2.5, PM4/5, PM10 and TSP mass concentrations during 8-h monitoring sessions in an urban background site (Como, Italy) in winter. A total of 16 sampling sessions were performed: measurements were analyzed using linear regression analysis. Absolute deviations between techniques were calculated and discussed. The UFP concentrations measured using a condensation particle counter were clearly overestimated compared with the reference instrument (portable diffusion charger), with an absolute deviation that appeared to increase with the UFP concentration. The comparison of different light-scattering devices (photometers - 'PHOTs') indicated an over-estimation of two of the tested instruments (PHOT-2 and PHOT-3) with respect to the one used as the reference (PHOT-1) regarding the measurement of the size-fractioned PM, with the only exception being PM4/5 . Further, the comparison of different light-scattering devices with filter-based samplers indicated that direct-reading devices tend to over-estimate (PHOT-2, PHOT-3) or under-estimate (PHOT-1) the PM concentrationsAbstract: The objective of this study was to compare the use of co-located real-time devices and gravimetric samplers to measure ultrafine particles (UFP) and size-fractionated PM mass concentrations. The results contribute to evaluating the comparability of different monitoring instruments for size-fractionated PM concentrations. Paired light scattering devices and gravimetric samplers were used to measure the PM1, PM2.5, PM4/5, PM10 and TSP mass concentrations during 8-h monitoring sessions in an urban background site (Como, Italy) in winter. A total of 16 sampling sessions were performed: measurements were analyzed using linear regression analysis. Absolute deviations between techniques were calculated and discussed. The UFP concentrations measured using a condensation particle counter were clearly overestimated compared with the reference instrument (portable diffusion charger), with an absolute deviation that appeared to increase with the UFP concentration. The comparison of different light-scattering devices (photometers - 'PHOTs') indicated an over-estimation of two of the tested instruments (PHOT-2 and PHOT-3) with respect to the one used as the reference (PHOT-1) regarding the measurement of the size-fractioned PM, with the only exception being PM4/5 . Further, the comparison of different light-scattering devices with filter-based samplers indicated that direct-reading devices tend to over-estimate (PHOT-2, PHOT-3) or under-estimate (PHOT-1) the PM concentrations from gravimetric analysis. The comparison of different filter-based samplers showed that the observed over-estimation error increased with increasing PM concentration levels; however, the good level of agreement between the investigated methods allowed them to be classified as comparable, although they cannot be characterized as having reciprocal predictability. Ambient relative humidity was correlated with the absolute error resulting from the comparison of direct-reading vs. filter-based techniques, as well as among different filter-based samplers for the same PM fraction. Highlights: The performances of different devices for measurement of UFP and PM were compared. The results were analyzed using linear regression analysis and absolute deviations. The overestimation error increased with increasing PM and UFP concentrations. The studied direct-reading methods can be generally classified as comparable. The absolute error is correlated with relative humidity in filter-based techniques. … (more)
- Is Part Of:
- Atmospheric environment. Volume 154(2017)
- Journal:
- Atmospheric environment
- Issue:
- Volume 154(2017)
- Issue Display:
- Volume 154, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 154
- Issue:
- 2017
- Issue Sort Value:
- 2017-0154-2017-0000
- Page Start:
- 274
- Page End:
- 284
- Publication Date:
- 2017-04
- Subjects:
- Urban background -- PM concentration -- Gravimetric analysis -- Direct reading instrument -- Intercomparison
CPC Condensation Particle Counter -- DSC Diffusion Size Classifier -- PHOT Photometer -- PCIS Personal Cascade Impactor Sampler -- PM Particulate Matter -- UFP Ultrafine Particles
Air -- Pollution -- Periodicals
Air -- Pollution -- Meteorological aspects -- Periodicals
551.51 - Journal URLs:
- http://www.sciencedirect.com/web-editions/journal/13522310 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.atmosenv.2017.01.054 ↗
- Languages:
- English
- ISSNs:
- 1352-2310
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1767.120000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1226.xml