A low-cost smartphone-based platform for highly sensitive point-of-care testing with persistent luminescent phosphors. Issue 6 (3rd February 2017)
- Record Type:
- Journal Article
- Title:
- A low-cost smartphone-based platform for highly sensitive point-of-care testing with persistent luminescent phosphors. Issue 6 (3rd February 2017)
- Main Title:
- A low-cost smartphone-based platform for highly sensitive point-of-care testing with persistent luminescent phosphors
- Authors:
- Paterson, Andrew S.
Raja, Balakrishnan
Mandadi, Vinay
Townsend, Blane
Lee, Miles
Buell, Alex
Vu, Binh
Brgoch, Jakoah
Willson, Richard C. - Abstract:
- Abstract : Time-gated imaging on a smartphone of a lateral flow test strip run with persistent luminescent nanophosphors. Abstract : Through their computational power and connectivity, smartphones are poised to rapidly expand telemedicine and transform healthcare by enabling better personal health monitoring and rapid diagnostics. Recently, a variety of platforms have been developed to enable smartphone-based point-of-care testing using imaging-based readout with the smartphone camera as the detector. Fluorescent reporters have been shown to improve the sensitivity of assays over colorimetric labels, but fluorescence readout necessitates incorporating optical hardware into the detection system, adding to the cost and complexity of the device. Here we present a simple, low-cost smartphone-based detection platform for highly sensitive luminescence imaging readout of point-of-care tests run with persistent luminescent phosphors as reporters. The extremely bright and long-lived emission of persistent phosphors allows sensitive analyte detection with a smartphone by a facile time-gated imaging strategy. Phosphors are first briefly excited with the phone's camera flash, followed by switching off the flash, and subsequent imaging of phosphor luminescence with the camera. Using this approach, we demonstrate detection of human chorionic gonadotropin using a lateral flow assay and the smartphone platform with strontium aluminate nanoparticles as reporters, giving a detection limit ofAbstract : Time-gated imaging on a smartphone of a lateral flow test strip run with persistent luminescent nanophosphors. Abstract : Through their computational power and connectivity, smartphones are poised to rapidly expand telemedicine and transform healthcare by enabling better personal health monitoring and rapid diagnostics. Recently, a variety of platforms have been developed to enable smartphone-based point-of-care testing using imaging-based readout with the smartphone camera as the detector. Fluorescent reporters have been shown to improve the sensitivity of assays over colorimetric labels, but fluorescence readout necessitates incorporating optical hardware into the detection system, adding to the cost and complexity of the device. Here we present a simple, low-cost smartphone-based detection platform for highly sensitive luminescence imaging readout of point-of-care tests run with persistent luminescent phosphors as reporters. The extremely bright and long-lived emission of persistent phosphors allows sensitive analyte detection with a smartphone by a facile time-gated imaging strategy. Phosphors are first briefly excited with the phone's camera flash, followed by switching off the flash, and subsequent imaging of phosphor luminescence with the camera. Using this approach, we demonstrate detection of human chorionic gonadotropin using a lateral flow assay and the smartphone platform with strontium aluminate nanoparticles as reporters, giving a detection limit of ≈45 pg mL −1 (1.2 pM) in buffer. Time-gated imaging on a smartphone can be readily adapted for sensitive and potentially quantitative testing using other point-of-care formats, and is workable with a variety of persistent luminescent materials. … (more)
- Is Part Of:
- Lab on a chip. Volume 17:Issue 6(2017)
- Journal:
- Lab on a chip
- Issue:
- Volume 17:Issue 6(2017)
- Issue Display:
- Volume 17, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 17
- Issue:
- 6
- Issue Sort Value:
- 2017-0017-0006-0000
- Page Start:
- 1051
- Page End:
- 1059
- Publication Date:
- 2017-02-03
- Subjects:
- Miniature electronic equipment -- Periodicals
Combinatorial chemistry -- Periodicals
Biotechnology -- Periodicals
543.0813 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/lc#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6lc01167e ↗
- Languages:
- English
- ISSNs:
- 1473-0197
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5137.730000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2337.xml