In vivo endorectal dosimetry of prostate tomotherapy using dual MOSkin detectors. (8th May 2015)
- Record Type:
- Journal Article
- Title:
- In vivo endorectal dosimetry of prostate tomotherapy using dual MOSkin detectors. (8th May 2015)
- Main Title:
- In vivo endorectal dosimetry of prostate tomotherapy using dual MOSkin detectors
- Authors:
- Alnaghy, Sarah J.
Deshpande, Shrikant
Cutajar, Dean L.
Berk, Kemal
Metcalfe, Peter
Rosenfeld, Anatoly B. - Abstract:
- Abstract : Verification of dose to the anterior rectal wall in helical tomotherapy to the prostate is important due to the close proximity of the rectal wall to the treatment field. The steep dose gradient makes these measurements challenging. A phantom‐based study was completed, aimed at developing a system for measurement of anterior rectal wall doses during hypofractionated prostate stereotactic body radiotherapy (SBRT) utilizing tomotherapy delivery. An array of four dual MO Skin ™ dosimeters, spaced 1 cm apart, was placed on a replica Rectafix® immobilization spacer device. This Perspex probe is a more rigid alternative to rectal balloons, to improve geometric reproducibility. The doses at each point were measured in real time and compared to doses calculated by the treatment planning system (TPS). Additionally, distance‐to‐agreement (DTA) measurements were acquired to assist in the comparison of measured and predicted doses. All dual MO Skin detectors measured dose to within ± 5 % of the TPS at the anterior rectal wall. Whilst several points were outside of experimental error, the largest deviation from the TPS predicted dose represented a DTA of only 1.3 mm, within the acceptable DTA tolerance of 3 mm. Larger deviations of up to −11.9% were observed for the posterior and side walls; however, if acceptable DTA measurements are accounted for, then an agreement of 75% was observed. Although larger differences were observed at the other rectal wall locations, the overallAbstract : Verification of dose to the anterior rectal wall in helical tomotherapy to the prostate is important due to the close proximity of the rectal wall to the treatment field. The steep dose gradient makes these measurements challenging. A phantom‐based study was completed, aimed at developing a system for measurement of anterior rectal wall doses during hypofractionated prostate stereotactic body radiotherapy (SBRT) utilizing tomotherapy delivery. An array of four dual MO Skin ™ dosimeters, spaced 1 cm apart, was placed on a replica Rectafix® immobilization spacer device. This Perspex probe is a more rigid alternative to rectal balloons, to improve geometric reproducibility. The doses at each point were measured in real time and compared to doses calculated by the treatment planning system (TPS). Additionally, distance‐to‐agreement (DTA) measurements were acquired to assist in the comparison of measured and predicted doses. All dual MO Skin detectors measured dose to within ± 5 % of the TPS at the anterior rectal wall. Whilst several points were outside of experimental error, the largest deviation from the TPS predicted dose represented a DTA of only 1.3 mm, within the acceptable DTA tolerance of 3 mm. Larger deviations of up to −11.9% were observed for the posterior and side walls; however, if acceptable DTA measurements are accounted for, then an agreement of 75% was observed. Although larger differences were observed at the other rectal wall locations, the overall effect of dose at these points was not as significant, given the lower doses. Despite the very high‐dose gradient region, real‐time measurements of the anterior rectal wall doses were within acceptable limits of TPS‐predicted doses. The differences between measured and planned data were due to difficulties in precisely locating each detector on the TPS dose grid, which presented large variations in dose between CT voxels in regions of steep dose gradients. The dual MO Skin system would, therefore, be a useful device for detecting errors in real time, such as patient shifts or incorrect setup, during tomotherapy of the prostate. PACS numbers: 87.53.Ly, 87.55.km, 87.55.N‐ … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 16:Number 3(2015)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 16:Number 3(2015)
- Issue Display:
- Volume 16, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 3
- Issue Sort Value:
- 2015-0016-0003-0000
- Page Start:
- 107
- Page End:
- 117
- Publication Date:
- 2015-05-08
- Subjects:
- helical tomotherapy -- MOSkin detector -- Rectafix -- rectal wall -- prostate cancer
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v16i3.5113 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1717.xml