36‐month data for the AdVance XP® male sling: results of a prospective multicentre study. (2nd December 2016)
- Record Type:
- Journal Article
- Title:
- 36‐month data for the AdVance XP® male sling: results of a prospective multicentre study. (2nd December 2016)
- Main Title:
- 36‐month data for the AdVance XP® male sling: results of a prospective multicentre study
- Authors:
- Bauer, Ricarda M.
Grabbert, Markus T.
Klehr, Benedikt
Gebhartl, Peter
Gozzi, Christian
Homberg, Roland
May, Florian
Rehder, Peter
Stief, Christian G.
Kretschmer, Alexander - Abstract:
- Abstract : Objectives: To evaluate the efficacy and safety of the AdVance XP ® sling (Boston Scientific, formerly American Medical Systems) in male stress urinary incontinence (SUI) after radical prostatectomy in a prospective multicentre study, as in recent years several studies have shown the effectiveness and safety of the AdVance sling for treating male SUI and in 2010 the second‐generation AdVance XP was introduced with several changes in the sling design and a new needle shape. Patients and Methods: In all, 115 patients were included. Patients with nocturnal UI, previous UI surgery, previous radiotherapy and a coaptive zone of <1 cm in the preoperative repositioning test were excluded. Postoperatively, a standardised 24‐h pad test, quality‐of‐life scores [International Quality of Life score (IQOL) and International Consultation on Incontinence Questionnaire short form (ICIQ‐UI SF)], visual analogue scale (VAS) for pain, five‐item version of the International Index of Erectile Function (IIEF‐5), International Prostate Symptom Score (IPSS) and Patient Global Impression of Improvement (PGI‐I) score, were performed. All patients with a 0–5 g pad test were defined as cured and improved with a reduction of urine loss of >50%. All others were classified as failures. Significance analysis was performed using the Wilcoxon test. Results: The mean (median) preoperative urine loss in the 24‐h pad test was 272.0 (272.0) g. After a follow‐up of 3 months (114 patients), 64.9% of theAbstract : Objectives: To evaluate the efficacy and safety of the AdVance XP ® sling (Boston Scientific, formerly American Medical Systems) in male stress urinary incontinence (SUI) after radical prostatectomy in a prospective multicentre study, as in recent years several studies have shown the effectiveness and safety of the AdVance sling for treating male SUI and in 2010 the second‐generation AdVance XP was introduced with several changes in the sling design and a new needle shape. Patients and Methods: In all, 115 patients were included. Patients with nocturnal UI, previous UI surgery, previous radiotherapy and a coaptive zone of <1 cm in the preoperative repositioning test were excluded. Postoperatively, a standardised 24‐h pad test, quality‐of‐life scores [International Quality of Life score (IQOL) and International Consultation on Incontinence Questionnaire short form (ICIQ‐UI SF)], visual analogue scale (VAS) for pain, five‐item version of the International Index of Erectile Function (IIEF‐5), International Prostate Symptom Score (IPSS) and Patient Global Impression of Improvement (PGI‐I) score, were performed. All patients with a 0–5 g pad test were defined as cured and improved with a reduction of urine loss of >50%. All others were classified as failures. Significance analysis was performed using the Wilcoxon test. Results: The mean (median) preoperative urine loss in the 24‐h pad test was 272.0 (272.0) g. After a follow‐up of 3 months (114 patients), 64.9% of the patients were cured and 31.6% had an improved continence status. The mean urine loss decreased significantly to 34.9 g ( P < 0.001), with a mean VAS score of 0.5, and mean PGI‐I of 1.5. After a follow‐up of 24 months (80 patients), 68.8% of the patients were cured and 22.5% had improved. The mean urine loss decreased significantly to 19.1 g ( P < 0.001), with a mean VAS score of 0.3, and mean PGI‐I of 1.5. After a follow‐up of 36 months (47 patients), 66.0% of the patients were cured and 23.4% had improved. The mean urine loss decreased significantly to 21.8 g ( P < 0.001), with a mean VAS score of 0.0, and mean PGI‐I of 1.6. The mean IQOL and ICIQ‐UI SF improved significantly (both P < 0.001) after 36 months. There were no significant postoperative changes in IIEF‐5 and IPSS. No intraoperative and no long‐term complications occurred. No erosion or explanations occurred. Conclusion: The AdVance XP shows good and stable effectiveness and low complication rates even at a mid‐term follow‐up of up to 36 months. … (more)
- Is Part Of:
- BJU international. Volume 119:Number 4(2017)
- Journal:
- BJU international
- Issue:
- Volume 119:Number 4(2017)
- Issue Display:
- Volume 119, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 119
- Issue:
- 4
- Issue Sort Value:
- 2017-0119-0004-0000
- Page Start:
- 626
- Page End:
- 630
- Publication Date:
- 2016-12-02
- Subjects:
- post‐prostatectomy incontinence -- male sling -- AdVance XP -- safety -- efficacy -- radical prostatectomy -- #Incontinence
Genitourinary organs -- Diseases -- Periodicals
Genitourinary organs -- Surgery -- Periodicals
Urology -- Periodicals
616.6 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1464-410X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/bju.13704 ↗
- Languages:
- English
- ISSNs:
- 1464-4096
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2105.758000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2395.xml