Shear Wave Elastography Is a Reliable and Repeatable Method for Measuring the Elastic Modulus of the Rectus Femoris Muscle and Patellar Tendon. (21st January 2017)
- Record Type:
- Journal Article
- Title:
- Shear Wave Elastography Is a Reliable and Repeatable Method for Measuring the Elastic Modulus of the Rectus Femoris Muscle and Patellar Tendon. (21st January 2017)
- Main Title:
- Shear Wave Elastography Is a Reliable and Repeatable Method for Measuring the Elastic Modulus of the Rectus Femoris Muscle and Patellar Tendon
- Authors:
- Taş, Serkan
Onur, Mehmet Ruhi
Yılmaz, Seval
Soylu, Abdullah Ruhi
Korkusuz, Feza - Abstract:
- Abstract : Objectives: The purpose of this study was to determine intraobserver, interobserver, and inter‐day reliability levels for stiffness measurements of the patellar tendon and rectus femoris muscle using shear wave elastography (SWE). Methods: This study was conducted on 12 healthy male individuals. Two examiners measured mean shear wave velocity values of the patellar tendons and rectus femoris muscles of both extremities using a 9L4 (4‐9 MHz) transducer and an Acuson S3000 ultrasound system (Siemens Medical Solutions, Mountain View, CA). The elasticity images were acquired by the Virtual Touch tissue imaging quantification technique (Siemens Medical Solutions). Measurements were repeated 20 minutes and 1 week after the first measurements. The reliability of SWE measurements was assessed by means of the intraclass correlation coefficient (ICC). Results: The 12 participants ranged in age from 19 to 33 years (mean age ± SD, 25.33 ± 4.56 years). For the patellar tendon stiffness measurements with SWE, it was found that intraobserver reliability (ICC, 0.91–0.92) and interday reliability (ICC, 0.81–0.83) were excellent, and interobserver reliability (ICC, 0.71) was good. For the rectus femoris muscle stiffness measurements with SWE, it was found that the intraobserver reliability (ICC, 0.93–0.94), interday reliability (ICC, 0.81–0.91), and interobserver reliability (ICC, 0.95) were perfect. Conclusions: Shear wave elastography using the Virtual Touch tissue imagingAbstract : Objectives: The purpose of this study was to determine intraobserver, interobserver, and inter‐day reliability levels for stiffness measurements of the patellar tendon and rectus femoris muscle using shear wave elastography (SWE). Methods: This study was conducted on 12 healthy male individuals. Two examiners measured mean shear wave velocity values of the patellar tendons and rectus femoris muscles of both extremities using a 9L4 (4‐9 MHz) transducer and an Acuson S3000 ultrasound system (Siemens Medical Solutions, Mountain View, CA). The elasticity images were acquired by the Virtual Touch tissue imaging quantification technique (Siemens Medical Solutions). Measurements were repeated 20 minutes and 1 week after the first measurements. The reliability of SWE measurements was assessed by means of the intraclass correlation coefficient (ICC). Results: The 12 participants ranged in age from 19 to 33 years (mean age ± SD, 25.33 ± 4.56 years). For the patellar tendon stiffness measurements with SWE, it was found that intraobserver reliability (ICC, 0.91–0.92) and interday reliability (ICC, 0.81–0.83) were excellent, and interobserver reliability (ICC, 0.71) was good. For the rectus femoris muscle stiffness measurements with SWE, it was found that the intraobserver reliability (ICC, 0.93–0.94), interday reliability (ICC, 0.81–0.91), and interobserver reliability (ICC, 0.95) were perfect. Conclusions: Shear wave elastography using the Virtual Touch tissue imaging quantification technique is a reliable and repeatable technique for patellar tendon and rectus femoris stiffness measurements according to intraobserver, interday, and interobserver ICC values. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 36:Number 3(2017)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 36:Number 3(2017)
- Issue Display:
- Volume 36, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 36
- Issue:
- 3
- Issue Sort Value:
- 2017-0036-0003-0000
- Page Start:
- 565
- Page End:
- 570
- Publication Date:
- 2017-01-21
- Subjects:
- muscle -- musculoskeletal ultrasound -- reliability -- shear wave elastography -- sonography -- tendon
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.7863/ultra.16.03032 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1771.xml