Traceable assigned values in external quality assessment schemes compared to those obtained by alternative procedure: a case study for Cu, Se and Zn in serum. Issue 1 (23rd September 2014)
- Record Type:
- Journal Article
- Title:
- Traceable assigned values in external quality assessment schemes compared to those obtained by alternative procedure: a case study for Cu, Se and Zn in serum. Issue 1 (23rd September 2014)
- Main Title:
- Traceable assigned values in external quality assessment schemes compared to those obtained by alternative procedure: a case study for Cu, Se and Zn in serum
- Authors:
- Patriarca, Marina
Weykamp, Cas
Arnaud, Josiane
Jones, Robert L.
Parsons, Patrick J.
Taylor, Andrew - Abstract:
- Abstract : International standards for the recognition of the competence of testing laboratories require that measurement results should be traceable to a conventionally agreed reference. Abstract : International standards for the recognition of the competence of testing laboratories require that measurement results should be traceable to a conventionally agreed reference. This should be achieved by appropriate calibration of equipment and method validation involving analysis of certified reference materials (CRM). However, these are costly and for many analytical procedures, few are available. Participation in external quality assessment schemes (EQAS) may provide a mean to support the laboratory traceability statement, if the values assigned to test samples are traceable to a stated reference. Values may be assigned to EQAS test samples by a variety of techniques but there has been no direct comparison of results obtained when these procedures are applied to the same samples. In this study, traceable values for Cu, Se and Zn concentrations were assigned to three batches of EQAS serum samples, by analysis by expert laboratories together with CRMs, and compared with those obtained by three other of the approaches described in ISO 13528; analysis by a definitive method (ID-ICP-MS); determination of robust consensus mean from the results of expert laboratories; robust consensus mean of results from EQAS participants. The assigned values (μmol L −1 ) ± expanded uncertainty (%)Abstract : International standards for the recognition of the competence of testing laboratories require that measurement results should be traceable to a conventionally agreed reference. Abstract : International standards for the recognition of the competence of testing laboratories require that measurement results should be traceable to a conventionally agreed reference. This should be achieved by appropriate calibration of equipment and method validation involving analysis of certified reference materials (CRM). However, these are costly and for many analytical procedures, few are available. Participation in external quality assessment schemes (EQAS) may provide a mean to support the laboratory traceability statement, if the values assigned to test samples are traceable to a stated reference. Values may be assigned to EQAS test samples by a variety of techniques but there has been no direct comparison of results obtained when these procedures are applied to the same samples. In this study, traceable values for Cu, Se and Zn concentrations were assigned to three batches of EQAS serum samples, by analysis by expert laboratories together with CRMs, and compared with those obtained by three other of the approaches described in ISO 13528; analysis by a definitive method (ID-ICP-MS); determination of robust consensus mean from the results of expert laboratories; robust consensus mean of results from EQAS participants. The assigned values (μmol L −1 ) ± expanded uncertainty (%) for the low, medium and high pools obtained by ID-ICP-MS were: Cu 13.37 ± 1.2, 21.03 ± 1.8, 28.73 ± 1.2; Se 0.74 ± 3.5, 1.51 ± 3.4, 3.11 ± 3.6; Zn 9.69 ± 4.9, 22.52 ± 1.5, 30.85 ± 3.8. Concentrations determined using the three other approaches were similar but the uncertainties increased as the methodologies became increasingly less rigorous. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 30:Issue 1(2015:Jan.)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 30:Issue 1(2015:Jan.)
- Issue Display:
- Volume 30, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 30
- Issue:
- 1
- Issue Sort Value:
- 2015-0030-0001-0000
- Page Start:
- 148
- Page End:
- 153
- Publication Date:
- 2014-09-23
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c4ja00260a ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1829.xml