Comparison between AMS 700™ CX and Coloplast™ Titan Inflatable Penile Prosthesis for Peyronie's Disease Treatment and Remodeling: Clinical Outcomes and Patient Satisfaction. (4th December 2012)
- Record Type:
- Journal Article
- Title:
- Comparison between AMS 700™ CX and Coloplast™ Titan Inflatable Penile Prosthesis for Peyronie's Disease Treatment and Remodeling: Clinical Outcomes and Patient Satisfaction. (4th December 2012)
- Main Title:
- Comparison between AMS 700™ CX and Coloplast™ Titan Inflatable Penile Prosthesis for Peyronie's Disease Treatment and Remodeling: Clinical Outcomes and Patient Satisfaction
- Authors:
- Chung, Eric
Solomon, Matthew
DeYoung, Ling
Brock, Gerald B. - Abstract:
- ABSTRACT: Introduction. The implantation of inflatable penile prosthesis (IPP) with simultaneous manual penile remodeling allows for men to undergo a single procedure aimed at correcting both the penile deformity/curvature and erectile dysfunction (ED). Aim. To evaluate the clinical outcomes and patient satisfaction in men with Peyronie's disease (PD) and ED who underwent AMS 700™ CX and the newer Coloplast™ Titan inflatable penile prosthesis (IPP) implant. Main Outcome Measures. Patient demographics, type of IPP, clinical outcomes, post‐implant sexual characteristics, and overall patient satisfaction. Methods. A single‐center retrospective review of clinical database and prospective telephone survey were conducted in all men with PD who underwent IPP between January 2006 and November 2010. Results. A total of 138 patients with an average age of 57.7 (32 to 80) underwent AMS 700 CX (88 patients) and Coloplast Titans (50 patients) IPP implantation during the 5‐year period. The majority of patients (91%) had only one IPP implantation. The IPP clinical outcomes include eight (6%) revision surgery for device malfunction and three (2%) device explantation for prosthesis infection. While there was no statistically significance in device survival between the two devices, the trend favored AMS 700 CX over Titan (5‐year Kaplan‐Meier estimates of mechanical survival were 91% vs. 87%, P > 0.05) and both IPPs provided similar penile straightening without the need for revisionABSTRACT: Introduction. The implantation of inflatable penile prosthesis (IPP) with simultaneous manual penile remodeling allows for men to undergo a single procedure aimed at correcting both the penile deformity/curvature and erectile dysfunction (ED). Aim. To evaluate the clinical outcomes and patient satisfaction in men with Peyronie's disease (PD) and ED who underwent AMS 700™ CX and the newer Coloplast™ Titan inflatable penile prosthesis (IPP) implant. Main Outcome Measures. Patient demographics, type of IPP, clinical outcomes, post‐implant sexual characteristics, and overall patient satisfaction. Methods. A single‐center retrospective review of clinical database and prospective telephone survey were conducted in all men with PD who underwent IPP between January 2006 and November 2010. Results. A total of 138 patients with an average age of 57.7 (32 to 80) underwent AMS 700 CX (88 patients) and Coloplast Titans (50 patients) IPP implantation during the 5‐year period. The majority of patients (91%) had only one IPP implantation. The IPP clinical outcomes include eight (6%) revision surgery for device malfunction and three (2%) device explantation for prosthesis infection. While there was no statistically significance in device survival between the two devices, the trend favored AMS 700 CX over Titan (5‐year Kaplan‐Meier estimates of mechanical survival were 91% vs. 87%, P > 0.05) and both IPPs provided similar penile straightening without the need for revision surgery. Most men (79%) reported great satisfaction following CX or Titan implants with greater than two thirds of men reported greater self‐confidence and 82% of patients would undergo the same operation again. Conclusions. AMS 700™ CX and Coloplast™ Titan IPP implantation and penile remodeling appeared to provide permanent penile straightening and high patient satisfaction without an increase risk of revision surgery.Chung E, Solomon M, DeYoung L, and Brock GB. Comparison between AMS 700™ CX and Coloplast™ Titan inflatable penile prosthesis for Peyronie's disease treatment and remodeling: Clinical outcomes and patient satisfaction. J Sex Med 2013;10:2855–2860. … (more)
- Is Part Of:
- Journal of sexual medicine. Volume 10:Number 11(2013:Nov.)
- Journal:
- Journal of sexual medicine
- Issue:
- Volume 10:Number 11(2013:Nov.)
- Issue Display:
- Volume 10, Issue 11 (2013)
- Year:
- 2013
- Volume:
- 10
- Issue:
- 11
- Issue Sort Value:
- 2013-0010-0011-0000
- Page Start:
- 2855
- Page End:
- 2860
- Publication Date:
- 2012-12-04
- Subjects:
- Peyronie's Disease -- Inflatable Penile Prosthesis -- Penile Remodeling -- Device Survival -- AMS 700 and Titan Device -- Patient Satisfaction
Sexual disorders -- Periodicals
Sex -- Periodicals
Sexual health -- Periodicals
616.69005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1743-6109 ↗
http://www.blackwell-synergy.com/openurl?genre=journal&eissn=1743-6109 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jsm ↗
https://academic.oup.com/jsm ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jsm.12009 ↗
- Languages:
- English
- ISSNs:
- 1743-6095
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5064.060000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 302.xml