An experimental study of the influence of a walking occupant on three air distribution methods. (February 2015)
- Record Type:
- Journal Article
- Title:
- An experimental study of the influence of a walking occupant on three air distribution methods. (February 2015)
- Main Title:
- An experimental study of the influence of a walking occupant on three air distribution methods
- Authors:
- Wu, Weiqin
Lin, Zhang - Abstract:
- Abstract: Most indoor air studies have not considered the influence of walking occupants. However, the occupants of many air conditioned rooms are a mixture of sedentary and walking occupants, such as in an opening plain office. In this paper, a series of tests are conducted under three air distribution methods (stratum ventilation, displacement ventilation and mixing ventilation) with a real walking occupant. The occupant walks at a speed of 1.5 m/s along two different walking routes. Velocity, temperature and CO2 concentration are measured to find the influence on air distribution. The results show that a short walk does not change the temperature or CO2 concentration profiles. When the walk lasts for a long time (30 min in this study), the walking occupant causes mixing effect. The influence under mixing ventilation is the smallest. The influence under stratum ventilation is smaller than that under displacement ventilation. The ventilation efficiency of stratum ventilation is still higher than that of mixing ventilation. Stratum ventilation and mixing ventilation recover from the influence more quickly than displacement ventilation. The results show the application potential of stratum ventilation with frequently walking occupants. Highlights: The influence of a walking occupant was studied under three air distribution methods. Short walk does not cause the airflow pattern to change. Stratum ventilation almost keeps its airflow pattern during the walking process. StratumAbstract: Most indoor air studies have not considered the influence of walking occupants. However, the occupants of many air conditioned rooms are a mixture of sedentary and walking occupants, such as in an opening plain office. In this paper, a series of tests are conducted under three air distribution methods (stratum ventilation, displacement ventilation and mixing ventilation) with a real walking occupant. The occupant walks at a speed of 1.5 m/s along two different walking routes. Velocity, temperature and CO2 concentration are measured to find the influence on air distribution. The results show that a short walk does not change the temperature or CO2 concentration profiles. When the walk lasts for a long time (30 min in this study), the walking occupant causes mixing effect. The influence under mixing ventilation is the smallest. The influence under stratum ventilation is smaller than that under displacement ventilation. The ventilation efficiency of stratum ventilation is still higher than that of mixing ventilation. Stratum ventilation and mixing ventilation recover from the influence more quickly than displacement ventilation. The results show the application potential of stratum ventilation with frequently walking occupants. Highlights: The influence of a walking occupant was studied under three air distribution methods. Short walk does not cause the airflow pattern to change. Stratum ventilation almost keeps its airflow pattern during the walking process. Stratum ventilation has the potential for application with frequently walking occupants. … (more)
- Is Part Of:
- Building and environment. Volume 85(2015)
- Journal:
- Building and environment
- Issue:
- Volume 85(2015)
- Issue Display:
- Volume 85, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 85
- Issue:
- 2015
- Issue Sort Value:
- 2015-0085-2015-0000
- Page Start:
- 211
- Page End:
- 219
- Publication Date:
- 2015-02
- Subjects:
- Stratum ventilation -- Displacement ventilation -- Walking occupant -- Airflow pattern -- Temperature profile -- CO2 concentration
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2014.12.009 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1943.xml