TL response of LiF:Mg, Cu, P (GR200A and GR207A) exposed to high-energy 12C ions. (July 2015)
- Record Type:
- Journal Article
- Title:
- TL response of LiF:Mg, Cu, P (GR200A and GR207A) exposed to high-energy 12C ions. (July 2015)
- Main Title:
- TL response of LiF:Mg, Cu, P (GR200A and GR207A) exposed to high-energy 12C ions
- Authors:
- Zhang, X.Y.
Chen, L.
Luo, P.
Ju, Y.Q.
Zhang, H.B.
Ma, F.
Ge, H.L.
Zhang, Y.B.
Wan, B.
Li, Y.Y.
Xu, X.W.
Mao, W. - Abstract:
- Abstract: The characteristics of nat ., 7 LiF:Mg, Cu, P thermoluminescent detectors exposed to high-energy 12 C (165 MeV/nucleon) ions and 60 Co γ -rays have been investigated. Through a careful analysis of the glow curves by the GlowFit program, it is found that the relative amplitude of satellite peaks 3, 5, 6 and 7 to peak 4, measured after irradiated with high-energy 12 C ions, is higher than that with 60 Co γ -rays for both types of TL detectors. It is observed that nat ., 7 LiF:Mg, Cu, P thermoluminescent detectors would also exhibit a good linear dose response when the delivered dose of high-energy 12 C ions is in the range from 100 mGy to 1600 mGy. Furthermore, the relative efficiency of the nat ., 7 LiF:Mg, Cu, P thermoluminescent detectors is independent of the absorbed dose in the linear dose response range. Compared to previously published data, the relative efficiency of the 7 LiF:Mg, Cu, P TL detectors decreases with increasing LET values. Highlights: GR200A and GR207A detectors exposed to high-energy 12 C ions are studied. Glow curves induced by high-energy 12 C ions and 60 Co γ-rays are different. Good linear dose response of GR200A and GR207A detectors are observed. Relative TL efficiency of LiF:Mg, Cu, P are independent of the absorbed dose. Efficiency of GR207A detector decreases with increasing LET values.
- Is Part Of:
- Radiation measurements. Volume 78(2015:Jul.)
- Journal:
- Radiation measurements
- Issue:
- Volume 78(2015:Jul.)
- Issue Display:
- Volume 78 (2015)
- Year:
- 2015
- Volume:
- 78
- Issue Sort Value:
- 2015-0078-0000-0000
- Page Start:
- 23
- Page End:
- 27
- Publication Date:
- 2015-07
- Subjects:
- Thermoluminescent detectors -- GR200A and GR207A -- High-energy 12C ions -- Dose response -- Thermoluminescent efficiency
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2014.10.004 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1779.xml