Real‐Time In Vivo Hepatotoxicity Monitoring through Chromophore‐Conjugated Photon‐Upconverting Nanoprobes. Issue 15 (15th March 2017)
- Record Type:
- Journal Article
- Title:
- Real‐Time In Vivo Hepatotoxicity Monitoring through Chromophore‐Conjugated Photon‐Upconverting Nanoprobes. Issue 15 (15th March 2017)
- Main Title:
- Real‐Time In Vivo Hepatotoxicity Monitoring through Chromophore‐Conjugated Photon‐Upconverting Nanoprobes
- Authors:
- Peng, Juanjuan
Samanta, Animesh
Zeng, Xiao
Han, Sanyang
Wang, Lu
Su, Dongdong
Loong, Daniel Teh Boon
Kang, Nam‐Young
Park, Sung‐Jin
All, Angelo Homayoun
Jiang, Wenxuan
Yuan, Lin
Liu, Xiaogang
Chang, Young‐Tae - Abstract:
- Abstract: Drug toxicity is a long‐standing concern of modern medicine. A typical anti‐pain/fever drug paracetamol often causes hepatotoxicity due to peroxynitrite ONOO − . Conventional blood tests fail to offer real‐time unambiguous visualization of such hepatotoxicity in vivo. Here we report a luminescent approach to evaluate acute hepatotoxicity in vivo by chromophore‐conjugated upconversion nanoparticles. Upon injection, these nanoprobes mainly accumulate in the liver and the luminescence of nanoparticles remains suppressed owing to energy transfer to the chromophore. ONOO − can readily bleach the chromophore and thus recover the luminescence, the presence of ONOO − in the liver leads to fast restoring of the near‐infrared emission. Taking advantages of the high tissue‐penetration capability of near‐infrared excitation/emission, these nanoprobes achieve real‐time monitoring of hepatotoxicity in living animals, thereby providing a convenient screening strategy for assessing hepatotoxicity of synthetic drugs. Abstract : Drug toxicity : A chromophore‐conjugated photon‐upconverting nanoprobe was developed for rapid and sensitive detection of the peroxynitrite anion ONOO − in aqueous solution. The nanoprobe was used for real‐time monitoring of the hepatotoxicity of synthetic drugs in living animals.
- Is Part Of:
- Angewandte Chemie international edition. Volume 56:Issue 15(2017)
- Journal:
- Angewandte Chemie international edition
- Issue:
- Volume 56:Issue 15(2017)
- Issue Display:
- Volume 56, Issue 15 (2017)
- Year:
- 2017
- Volume:
- 56
- Issue:
- 15
- Issue Sort Value:
- 2017-0056-0015-0000
- Page Start:
- 4165
- Page End:
- 4169
- Publication Date:
- 2017-03-15
- Subjects:
- biosensors -- fluorescent probes -- hepatotoxicity -- nanotechnology -- paracetamol
Chemistry -- Periodicals
540 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-3773 ↗
http://www.interscience.wiley.com/jpages/1433-7851 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/anie.201612020 ↗
- Languages:
- English
- ISSNs:
- 1433-7851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0902.000500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2384.xml