Accuracy diagrams: a novel way to illustrate uncertainty of estimated GFR. (3rd April 2017)
- Record Type:
- Journal Article
- Title:
- Accuracy diagrams: a novel way to illustrate uncertainty of estimated GFR. (3rd April 2017)
- Main Title:
- Accuracy diagrams: a novel way to illustrate uncertainty of estimated GFR
- Authors:
- Björk, Jonas
Grubb, Anders
Sterner, Gunnar
Bäck, Sten-Erik
Nyman, Ulf - Abstract:
- Abstract: Most studies that validate GFR equations present accuracy results stratified by measured GFR (mGFR; diagnostic correctness) or by estimated GFR (eGFR; diagnostic predictiveness) only, without a clear distinction in interpretation. The accuracy of a GFR equation is normally reported in percent (e.g. P30 ), but is often misinterpreted when stratified by eGFR. The aim of the study was to develop new accuracy measures and diagrams that allow straightforward interpretations and illustrations of the uncertainty in eGFR in clinical practice. We applied quantile regression to the distribution of estimation errors for two creatinine-based GFR equations, LM-REV and CKD-EPI, in a clinical cohort ( n = 3495) referred for GFR measurement (plasma clearance of iohexol). Measures of bias and precision and accuracy intervals (AIs) were expressed in mL/min/1.73 m 2 . Diagrams with AIs were chosen as a novel way to present the error margin in eGFR at a pre-specified certainty level. It was shown that creatinine-based equations are still quite inaccurate in that large estimation errors could not be ruled out with satisfactory certainty. As an example, the 75% AI for the most accurate equation, LM-REV, was approximately ±10 mL/min/1.73 m 2 at eGFR = 45 mL/min/1.73 m 2, whereas it ranged between −13 and +20 mL/min/1.73 m 2 at eGFR = 90 mL/min/1.73 m 2 . Accuracy intervals presented in diagrams can be used to illustrate the uncertainty of eGFR. Future validation studies should assessAbstract: Most studies that validate GFR equations present accuracy results stratified by measured GFR (mGFR; diagnostic correctness) or by estimated GFR (eGFR; diagnostic predictiveness) only, without a clear distinction in interpretation. The accuracy of a GFR equation is normally reported in percent (e.g. P30 ), but is often misinterpreted when stratified by eGFR. The aim of the study was to develop new accuracy measures and diagrams that allow straightforward interpretations and illustrations of the uncertainty in eGFR in clinical practice. We applied quantile regression to the distribution of estimation errors for two creatinine-based GFR equations, LM-REV and CKD-EPI, in a clinical cohort ( n = 3495) referred for GFR measurement (plasma clearance of iohexol). Measures of bias and precision and accuracy intervals (AIs) were expressed in mL/min/1.73 m 2 . Diagrams with AIs were chosen as a novel way to present the error margin in eGFR at a pre-specified certainty level. It was shown that creatinine-based equations are still quite inaccurate in that large estimation errors could not be ruled out with satisfactory certainty. As an example, the 75% AI for the most accurate equation, LM-REV, was approximately ±10 mL/min/1.73 m 2 at eGFR = 45 mL/min/1.73 m 2, whereas it ranged between −13 and +20 mL/min/1.73 m 2 at eGFR = 90 mL/min/1.73 m 2 . Accuracy intervals presented in diagrams can be used to illustrate the uncertainty of eGFR. Future validation studies should assess the variability in the predictiveness of eGFR across populations and clinical settings using tools and performance measures that are easy to interpret. … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 77:Number 3(2017)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 77:Number 3(2017)
- Issue Display:
- Volume 77, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 3
- Issue Sort Value:
- 2017-0077-0003-0000
- Page Start:
- 199
- Page End:
- 204
- Publication Date:
- 2017-04-03
- Subjects:
- Renal insufficiency -- reproducibility of results -- statistical regression -- bias (epidemiology) -- predictive value of tests -- clinical decision-making
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365513.2017.1292362 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 647.xml