Can We Use the Fellow Eye Biometric Data to Predict IOL Power?. (4th May 2017)
- Record Type:
- Journal Article
- Title:
- Can We Use the Fellow Eye Biometric Data to Predict IOL Power?. (4th May 2017)
- Main Title:
- Can We Use the Fellow Eye Biometric Data to Predict IOL Power?
- Authors:
- De Bernardo, Maddalena
Zeppa, Lucio
Forte, Raimondo
Cennamo, Michela
Caliendo, Luisa
Zeppa, Lucia
Rosa, Nicola - Abstract:
- ABSTRACT: Purpose : To study the correlation between right (RE) and left eye (LE) keratometry readings (K) and axial lengths (AL) in a population-based sample of normal subjects. Methods : In a cross-sectional retrospective study conducted at S. Giuseppe Moscati Hospital, Avellino, Italy, 4516 eyes of 2258 patients with a mean age of 67 ± 16.36 years (range 18–96 years) were included. Partial coherence interferometry data obtained in right (RE) and left (LE) eyes were analyzed and correlated. Results : The average K was 44.01 ± 1.50 diopters (D) (range 39.09–49.89 D) in the RE and 44.04 ± 1.53 D (range 39.63–51.89 D) in the LE (p = 0.0075). 4.5% of the patients (101) presented with differences in the corneal power ≥ 1 D, corresponding to a difference of roughly 1 D in the IOL power. The average AL was 23.89 ± 1.77 mm (range 19.09–35.15 mm) in the RE and 23.84 ± 1.68 mm (range 19.23–35.04 mm) in the LE (p = 0.0018). 19.2% of the patients (433) presented with differences in the AL ≥ 0.4 mm, corresponding to a difference of roughly 1 D in the IOL power. Conclusions : In calculating the IOL power, we must be aware of these results when we measure the fellow eye to validate the measurements in the first eye. In the case of postcataract refractive error, the outcome could be used for the second eye only when symmetric biometric findings are present.
- Is Part Of:
- Seminars in ophthalmology. Volume 32:Number 3(2017)
- Journal:
- Seminars in ophthalmology
- Issue:
- Volume 32:Number 3(2017)
- Issue Display:
- Volume 32, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2017-0032-0003-0000
- Page Start:
- 363
- Page End:
- 370
- Publication Date:
- 2017-05-04
- Subjects:
- Anisometropia -- axial length -- IOL calculation -- keratometry
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
Eye -- Surgery -- Periodicals
617.7005 - Journal URLs:
- http://informahealthcare.com/loi/sio ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/08820538.asp ↗ - DOI:
- 10.3109/08820538.2015.1096400 ↗
- Languages:
- English
- ISSNs:
- 0882-0538
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8239.456650
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 430.xml