Safety of the Wearable Cardioverter Defibrillator (WCD) in Patients with Implanted Pacemakers. Issue 3 (8th February 2017)
- Record Type:
- Journal Article
- Title:
- Safety of the Wearable Cardioverter Defibrillator (WCD) in Patients with Implanted Pacemakers. Issue 3 (8th February 2017)
- Main Title:
- Safety of the Wearable Cardioverter Defibrillator (WCD) in Patients with Implanted Pacemakers
- Authors:
- SCHMITT, JOERN
ABACI, GUEZINE
JOHNSON, VICTORIA
ERKAPIC, DAMIR
GEMEIN, CHRISTOPHER
CHASAN, RITVAN
WEIPERT, KAY
HAMM, CHRISTIAN W.
KLEIN, HELMUT U. - Abstract:
- Abstract : Background: The wearable cardioverter defibrillator (WCD) is an important approach for better risk stratification, applied to patients considered to be at high risk of sudden arrhythmic death. Patients with implanted pacemakers may also become candidates for use of the WCD. However, there is a potential risk that pacemaker signals may mislead the WCD detection algorithm and cause inappropriate WCD shock delivery. The aim of the study was to test the impact of different types of pacing, various right ventricular (RV) lead positions, and pacing modes for potential misleading of the WCD detection algorithm. Methods: Sixty patients with implanted pacemakers received the WCD for a short time and each pacing mode (AAI, VVI, and DDD) was tested for at least 30 seconds in unipolar and bipolar pacing configuration. In case of triggering the WCD detection algorithm and starting the sequence of arrhythmia alarms, shock delivery was prevented by pushing of the response buttons. Results: In six of 60 patients (10%), continuous unipolar pacing in DDD mode triggered the WCD detection algorithm. In no patient, triggering occurred with bipolar DDD pacing, unipolar and bipolar AAI, and VVI pacing. Triggering was independent of pacing amplitude, RV pacing lead position, and pulse generator implantation site. Conclusion: Unipolar DDD pacing bears a high risk of false triggering of the WCD detection algorithm. Other types of unipolar pacing and all bipolar pacing modes do not seem toAbstract : Background: The wearable cardioverter defibrillator (WCD) is an important approach for better risk stratification, applied to patients considered to be at high risk of sudden arrhythmic death. Patients with implanted pacemakers may also become candidates for use of the WCD. However, there is a potential risk that pacemaker signals may mislead the WCD detection algorithm and cause inappropriate WCD shock delivery. The aim of the study was to test the impact of different types of pacing, various right ventricular (RV) lead positions, and pacing modes for potential misleading of the WCD detection algorithm. Methods: Sixty patients with implanted pacemakers received the WCD for a short time and each pacing mode (AAI, VVI, and DDD) was tested for at least 30 seconds in unipolar and bipolar pacing configuration. In case of triggering the WCD detection algorithm and starting the sequence of arrhythmia alarms, shock delivery was prevented by pushing of the response buttons. Results: In six of 60 patients (10%), continuous unipolar pacing in DDD mode triggered the WCD detection algorithm. In no patient, triggering occurred with bipolar DDD pacing, unipolar and bipolar AAI, and VVI pacing. Triggering was independent of pacing amplitude, RV pacing lead position, and pulse generator implantation site. Conclusion: Unipolar DDD pacing bears a high risk of false triggering of the WCD detection algorithm. Other types of unipolar pacing and all bipolar pacing modes do not seem to mislead the WCD detection algorithm. Therefore, patients with no reprogrammable unipolar DDD pacing should not become candidates for the WCD. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 40:Issue 3(2017)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 40:Issue 3(2017)
- Issue Display:
- Volume 40, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 40
- Issue:
- 3
- Issue Sort Value:
- 2017-0040-0003-0000
- Page Start:
- 271
- Page End:
- 277
- Publication Date:
- 2017-02-08
- Subjects:
- wearable cardioverter defibrillator -- pacemaker -- pacing interaction -- detection algorithm -- inappropriate therapy -- double counting
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.12986 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1934.xml