Rapid characterization of trace aflatoxin B1 in groundnuts, wheat and maize by dispersive liquid‐liquid microextraction followed by direct electrospray probe tandem mass spectrometry. (13th March 2017)
- Record Type:
- Journal Article
- Title:
- Rapid characterization of trace aflatoxin B1 in groundnuts, wheat and maize by dispersive liquid‐liquid microextraction followed by direct electrospray probe tandem mass spectrometry. (13th March 2017)
- Main Title:
- Rapid characterization of trace aflatoxin B1 in groundnuts, wheat and maize by dispersive liquid‐liquid microextraction followed by direct electrospray probe tandem mass spectrometry
- Authors:
- Satarpai, Thiphol
Siripinyanond, Atitaya
Su, Hung
Shiea, Jentaie - Abstract:
- Abstract : Rationale: Aflatoxins are poisonous and cancer‐related chemical compounds commonly found in crops and plants. Aflatoxin B1 is the most toxic compound among aflatoxins and has been classified as group 1 carcinogenic to humans, especially in liver cancer. Herein, an ambient mass spectrometric method was developed for rapid characterization of trace aflatoxin B1 in peanuts. Methods: Direct electrospray probe tandem mass spectrometry (DEP‐MS/MS) was used to detect aflatoxin B1 in peanuts. To avoid the matrix effect, the aflatoxin B1 in the samples was extracted and concentrated by dispersive liquid–liquid microextraction. The mass spectrometer was operated in the positive ion mode to monitor the intact molecular ion ( m/z 313, MH + ) and product ion ( m/z 241) of aflatoxin B1 using multiple reaction monitoring. Results: Since no clean‐up procedure of the sample was required, the sampling step and the subsequent mass spectrometric detection of the aflatoxin B1 was completed in less than 5 min. The limit of detection of aflatoxin B1 is at the sub‐ppb level. The results obtained by DEP‐MS/MS were also validated by liquid chromatography/tandem mass spectrometry (LC/MS/MS). Recovery of aflatoxin B1 in the sample was evaluated by analyzing spiked aflatoxin B1 with LC/MS/MS to be 85% and DEP‐MS/MS to be 84%. Conclusions: DEP‐MS/MS combined with a simple dispersive liquid–liquid microextraction procedure was successfully used for the quantitative analysis of AFB1 in nutAbstract : Rationale: Aflatoxins are poisonous and cancer‐related chemical compounds commonly found in crops and plants. Aflatoxin B1 is the most toxic compound among aflatoxins and has been classified as group 1 carcinogenic to humans, especially in liver cancer. Herein, an ambient mass spectrometric method was developed for rapid characterization of trace aflatoxin B1 in peanuts. Methods: Direct electrospray probe tandem mass spectrometry (DEP‐MS/MS) was used to detect aflatoxin B1 in peanuts. To avoid the matrix effect, the aflatoxin B1 in the samples was extracted and concentrated by dispersive liquid–liquid microextraction. The mass spectrometer was operated in the positive ion mode to monitor the intact molecular ion ( m/z 313, MH + ) and product ion ( m/z 241) of aflatoxin B1 using multiple reaction monitoring. Results: Since no clean‐up procedure of the sample was required, the sampling step and the subsequent mass spectrometric detection of the aflatoxin B1 was completed in less than 5 min. The limit of detection of aflatoxin B1 is at the sub‐ppb level. The results obtained by DEP‐MS/MS were also validated by liquid chromatography/tandem mass spectrometry (LC/MS/MS). Recovery of aflatoxin B1 in the sample was evaluated by analyzing spiked aflatoxin B1 with LC/MS/MS to be 85% and DEP‐MS/MS to be 84%. Conclusions: DEP‐MS/MS combined with a simple dispersive liquid–liquid microextraction procedure was successfully used for the quantitative analysis of AFB1 in nut samples. Due to its high efficiency, it is promising in providing important toxicological information for food safety in the real world. Copyright © 2017 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 31:Number 8(2017)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 31:Number 8(2017)
- Issue Display:
- Volume 31, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2017-0031-0008-0000
- Page Start:
- 728
- Page End:
- 736
- Publication Date:
- 2017-03-13
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.7837 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1098.xml