Estimation of Serum YKL‐40 by Real‐Time Surface Plasmon Resonance Technology in North‐Indian Asthma Patients. Issue 2 (12th September 2016)
- Record Type:
- Journal Article
- Title:
- Estimation of Serum YKL‐40 by Real‐Time Surface Plasmon Resonance Technology in North‐Indian Asthma Patients. Issue 2 (12th September 2016)
- Main Title:
- Estimation of Serum YKL‐40 by Real‐Time Surface Plasmon Resonance Technology in North‐Indian Asthma Patients
- Authors:
- Naglot, Sarla
Aggarwal, Praveen
Dey, Sharmistha
Dalal, Krishna - Abstract:
- Abstract : Background: Many studies reported for estimating serum YKL‐40 using ELISA or RIA methods. This study introduces the plausible utilization of real‐time surface plasmon resonance (SPR) technology in investigating the expression of serum YKL‐40 protein levels and ELISA method for serum IgE in bronchial asthma. Methods: A commercially available BIAcore 2000 instrument, based on SPR technology, was utilized for assessing serum YKL‐40 levels in a control sample size of 45 and active sample size of 97. Antibody immobilization was optimized to obtain the best sensor performance and a sensitive analytic detection. A commercially available ELISA kit was utilized for detecting serum IgE to estimate allergic condition‐associated asthma. Results: The results of SPR technology could distinctly classify with highly statistical significance, the asthma severities by estimating the elevated levels of YKL‐40 in blood sera of minute quantities (up to 0.33 ng/ml), and thus differentiates superior utility in comparison with ELISA method. No statistically significant correlation of YKL‐40 and IgE was observed. Conclusions: Serum YKL‐40 may be used as a protein marker in classifying asthma severity by applying SPR technology as a reliable, label‐free, highly sensitive, and cost‐effective tool.
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 31:Issue 2(2017:Mar.)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 31:Issue 2(2017:Mar.)
- Issue Display:
- Volume 31, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 2
- Issue Sort Value:
- 2017-0031-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2016-09-12
- Subjects:
- Asthma severity -- Enzyme linked immunosorbent assay -- FEV1 -- Surface Plasmon Resonance technology -- YKL‐40
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22028 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2691.xml