New solid state cadmium-zinc-telluride technology for cardiac single photon emission computed tomographic myocardial perfusion imaging. (4th March 2017)
- Record Type:
- Journal Article
- Title:
- New solid state cadmium-zinc-telluride technology for cardiac single photon emission computed tomographic myocardial perfusion imaging. (4th March 2017)
- Main Title:
- New solid state cadmium-zinc-telluride technology for cardiac single photon emission computed tomographic myocardial perfusion imaging
- Authors:
- Alenazy, Ali B
Wells, R Glenn
Ruddy, Terrence D - Abstract:
- ABSTRACT: Introduction : Single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is well established as diagnostic test for patients with suspected or known coronary artery disease. New camera systems have been developed with cadmium-zinc-telluride (CZT) detectors, novel collimator designs and reconstruction software. Areas covered : We review the current state of cardiac SPECT, advances in conventional camera technology and the development and clinical validation of solid-state CZT cameras. Expert commentary : The development of CZT systems is timely and addresses current issues for clinical SPECT imaging. These systems have a significant increase in photon sensitivity, permitting much lower radiation patient doses at a time when the lay and medical communities are very concerned about the radiation doses resulting from medical imaging. The increased count sensitivity permits shorter acquisition times and greater patient throughput which may address the ongoing and increasing issue of decreased funding for healthcare and, particularly, diagnostic imaging. The improved image resolution should improve diagnostic accuracy and increase the value of SPECT imaging for management of patients with CAD at a time of significant competition from other imaging modalities.
- Is Part Of:
- Expert review of medical devices. Volume 14:Number 3(2017)
- Journal:
- Expert review of medical devices
- Issue:
- Volume 14:Number 3(2017)
- Issue Display:
- Volume 14, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 14
- Issue:
- 3
- Issue Sort Value:
- 2017-0014-0003-0000
- Page Start:
- 213
- Page End:
- 222
- Publication Date:
- 2017-03-04
- Subjects:
- SPECT -- cadmium-zinc-telluride -- radiation dose -- CAD -- PET
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/loi/erd ↗
http://www.future-drugs.com/loi/erd ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/17434440.2017.1296763 ↗
- Languages:
- English
- ISSNs:
- 1743-4440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3842.002986
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 484.xml