Carotid Doppler blood flow measurement during cardiopulmonary resuscitation is feasible: A first in man study. (November 2015)
- Record Type:
- Journal Article
- Title:
- Carotid Doppler blood flow measurement during cardiopulmonary resuscitation is feasible: A first in man study. (November 2015)
- Main Title:
- Carotid Doppler blood flow measurement during cardiopulmonary resuscitation is feasible: A first in man study
- Authors:
- Adedipe, Adeyinka A.
Fly, Deborah L.
Schwitz, Scott D.
Jorgenson, Dawn B.
Duric, Haris
Sayre, Michael R.
Nichol, Graham - Abstract:
- Abstract: Objective: High quality chest compressions are the cornerstone of effective cardiopulmonary resuscitation (CPR). There is no available method of real time noninvasive hemodynamic measurement and feedback to inform rescuers of the efficacy of compressions. Ultrasound-based measures of blood flow may provide immediate, noninvasive hemodynamic information. Our objective was to determine the feasibility and safety of using ultrasound to measure blood flow on patients with cardiac arrest. Methods: Study design This was a prospective cohort study in an emergency department setting. Subjects Included were patients receiving ongoing manual chest compressions for cardiac arrest. Excluded were those less than 18 years of age, incarcerated, pregnant, with neck injury, or obvious traumatic cause of arrest. Scan protocol Physicians recorded blood flow over the common carotid arteries during chest compressions with transverse and longitudinal color flow and Doppler using a portable ultrasound machine (CX30, Philips Healthcare., Andover, MA). Measurements Duration of scan time, and the median values for peak systolic (PSV), end-diastolic (EDV) and mean diastolic (MDV) carotid blood flow velocities were captured. Feasibility was defined as the proportion of eligible subjects upon whom ultrasound was initiated Safety was defined as availability of at least 5 min of scanning time. Results: Nineteen patients (56% of eligible) where enrolled and had ultrasound measurements attemptedAbstract: Objective: High quality chest compressions are the cornerstone of effective cardiopulmonary resuscitation (CPR). There is no available method of real time noninvasive hemodynamic measurement and feedback to inform rescuers of the efficacy of compressions. Ultrasound-based measures of blood flow may provide immediate, noninvasive hemodynamic information. Our objective was to determine the feasibility and safety of using ultrasound to measure blood flow on patients with cardiac arrest. Methods: Study design This was a prospective cohort study in an emergency department setting. Subjects Included were patients receiving ongoing manual chest compressions for cardiac arrest. Excluded were those less than 18 years of age, incarcerated, pregnant, with neck injury, or obvious traumatic cause of arrest. Scan protocol Physicians recorded blood flow over the common carotid arteries during chest compressions with transverse and longitudinal color flow and Doppler using a portable ultrasound machine (CX30, Philips Healthcare., Andover, MA). Measurements Duration of scan time, and the median values for peak systolic (PSV), end-diastolic (EDV) and mean diastolic (MDV) carotid blood flow velocities were captured. Feasibility was defined as the proportion of eligible subjects upon whom ultrasound was initiated Safety was defined as availability of at least 5 min of scanning time. Results: Nineteen patients (56% of eligible) where enrolled and had ultrasound measurements attempted during manual compressions. In one patient, scanning was not initiated because ongoing CPR efforts were terminated. Three patients were enrolled but had no images available for review. A total of 15 patients (78% of attempted) had ultrasound imaging saved. Most ( n = 10, 66%) had scanning times greater than 5 min (median 5 min 59 s, interquartile range 3 min 15 s to 8 min 25 s), median PSV was 67 cm s −1 (IQR 55–106), median EDV was 18 cm s −1 (IQR 12–27), and median MDV was 14 cm s −1 (IQR 9–18). Conclusions: Ultrasound measurement of common carotid artery blood flow during CPR is feasible. Further studies are necessary to correlate carotid blood flow to other hemodynamic measures and its effects on patient outcomes. … (more)
- Is Part Of:
- Resuscitation. Volume 96(2015)
- Journal:
- Resuscitation
- Issue:
- Volume 96(2015)
- Issue Display:
- Volume 96, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 96
- Issue:
- 2015
- Issue Sort Value:
- 2015-0096-2015-0000
- Page Start:
- 121
- Page End:
- 125
- Publication Date:
- 2015-11
- Subjects:
- Cardiac arrest -- Hemodynamically-guided resuscitation -- Ultrasound
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2015.07.024 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1523.xml