Multi‐use high/low‐temperature and pressure compatible portable chamber for in situ grazing‐incidence X‐ray scattering studies. (1st March 2013)
- Record Type:
- Journal Article
- Title:
- Multi‐use high/low‐temperature and pressure compatible portable chamber for in situ grazing‐incidence X‐ray scattering studies. (1st March 2013)
- Main Title:
- Multi‐use high/low‐temperature and pressure compatible portable chamber for in situ grazing‐incidence X‐ray scattering studies
- Authors:
- Ferrer, Pilar
Rubio‐Zuazo, Juan
Heyman, Catherine
Esteban‐Betegón, Fatima
Castro, Germán R. - Abstract:
- Abstract : The multipurpose portable ultra‐high‐vacuum‐compatible chamber described in detail in this article has been designed to carry out grazing‐incidence X‐ray scattering techniques on the BM25‐SpLine CRG beamline at the ESRF. The chamber has a cylindrical form, built on a 360° beryllium double‐ended conflate flange (CF) nipple. The main advantage of this chamber design is the wide sample temperature range, which may be varied between 60 and 1000 K. Other advantages of using a cylinder are that the wall thickness is reduced to a minimum value, keeping maximal solid angle accessibility and keeping wall absorption of the incoming X‐ray beam constant. The heat exchanger is a customized compact liquid‐nitrogen (LN2) continuous‐flow cryostat. LN2 is transferred from a storage Dewar through a vacuum‐isolated transfer line to the heat exchanger. The sample is mounted on a molybdenum support on the heat exchanger, which is equipped with a BORALECTRIC heater element. The chamber versatility extends to the operating pressure, ranging from ultra‐high vacuum (<10 −10 mbar) to high pressure (up to 3 × 10 3 mbar). In addition, it is equipped with several CF ports to allocate auxiliary components such as capillary gas‐inlet, viewports, leak valves, ion gun, turbo pump, etc., responding to a large variety of experiment requirements. A movable slits set‐up has been foreseen to reduce the background and diffuse scattering produced at the beryllium wall. Diffraction data can be recordedAbstract : The multipurpose portable ultra‐high‐vacuum‐compatible chamber described in detail in this article has been designed to carry out grazing‐incidence X‐ray scattering techniques on the BM25‐SpLine CRG beamline at the ESRF. The chamber has a cylindrical form, built on a 360° beryllium double‐ended conflate flange (CF) nipple. The main advantage of this chamber design is the wide sample temperature range, which may be varied between 60 and 1000 K. Other advantages of using a cylinder are that the wall thickness is reduced to a minimum value, keeping maximal solid angle accessibility and keeping wall absorption of the incoming X‐ray beam constant. The heat exchanger is a customized compact liquid‐nitrogen (LN2) continuous‐flow cryostat. LN2 is transferred from a storage Dewar through a vacuum‐isolated transfer line to the heat exchanger. The sample is mounted on a molybdenum support on the heat exchanger, which is equipped with a BORALECTRIC heater element. The chamber versatility extends to the operating pressure, ranging from ultra‐high vacuum (<10 −10 mbar) to high pressure (up to 3 × 10 3 mbar). In addition, it is equipped with several CF ports to allocate auxiliary components such as capillary gas‐inlet, viewports, leak valves, ion gun, turbo pump, etc., responding to a large variety of experiment requirements. A movable slits set‐up has been foreseen to reduce the background and diffuse scattering produced at the beryllium wall. Diffraction data can be recorded either with a point detector or with a bi‐dimensional CCD detector, or both detectors simultaneously. The system has been designed to carry out a multitude of experiments in a large variety of environments. The system feasibility is demonstrated by showing temperature‐dependence grazing‐incidence X‐ray diffraction and conductivity measurements on a 20 nm‐thick La0.7 Ca0.3 MnO3 thin film grown on a SrTiO3 (001) substrate. … (more)
- Is Part Of:
- Journal of synchrotron radiation. Volume 20:Part 3(2013)
- Journal:
- Journal of synchrotron radiation
- Issue:
- Volume 20:Part 3(2013)
- Issue Display:
- Volume 20, Issue 3, Part 3 (2013)
- Year:
- 2013
- Volume:
- 20
- Issue:
- 3
- Part:
- 3
- Issue Sort Value:
- 2013-0020-0003-0003
- Page Start:
- 474
- Page End:
- 481
- Publication Date:
- 2013-03-01
- Subjects:
- portable chamber -- in situ X‐ray scattering -- cooling–heating system -- environment set‐up -- mixed‐valence manganites -- oxygen vacancies -- atomic structure
Synchrotron radiation -- Periodicals
Free electron lasers -- Periodicals
539.73505 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1107/S16005775 ↗
http://journals.iucr.org/s/journalhomepage.html ↗
http://www.blackwell-synergy.com/openurl?genre=journal&issn=0909-0495 ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1107/S0909049513002598 ↗
- Languages:
- English
- ISSNs:
- 0909-0495
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5068.035000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1879.xml