Comparison of filtering methods for extracellular gastric slow wave recordings. Issue 1 (13th September 2012)
- Record Type:
- Journal Article
- Title:
- Comparison of filtering methods for extracellular gastric slow wave recordings. Issue 1 (13th September 2012)
- Main Title:
- Comparison of filtering methods for extracellular gastric slow wave recordings
- Authors:
- Paskaranandavadivel, N.
O'Grady, G.
Du, P.
K Cheng, L. - Abstract:
- Abstract: Background Extracellular recordings are used to define gastric slow wave propagation. Signal filtering is a key step in the analysis and interpretation of extracellular slow wave data; however, there is controversy and uncertainty regarding the appropriate filtering settings. This study investigated the effect of various standard filters on the morphology and measurement of extracellular gastric slow waves. Methods Experimental extracellular gastric slow waves were recorded from the serosal surface of the stomach from pigs and humans. Four digital filters: finite impulse response filter (0.05–1 Hz); Savitzky‐Golay filter (0–1.98 Hz); Bessel filter (2–100 Hz); and Butterworth filter (5–100 Hz); were applied on extracellular gastric slow wave signals to compare the changes temporally (morphology of the signal) and spectrally (signals in the frequency domain). Key Results The extracellular slow wave activity is represented in the frequency domain by a dominant frequency and its associated harmonics in diminishing power. Optimal filters apply cutoff frequencies consistent with the dominant slow wave frequency (3–5 cpm) and main harmonics (up to ∼2 Hz). Applying filters with cutoff frequencies above or below the dominant and harmonic frequencies was found to distort or eliminate slow wave signal content. Conclusions & Inferences Investigators must be cognizant of these optimal filtering practices when detecting, analyzing, and interpreting extracellular slow waveAbstract: Background Extracellular recordings are used to define gastric slow wave propagation. Signal filtering is a key step in the analysis and interpretation of extracellular slow wave data; however, there is controversy and uncertainty regarding the appropriate filtering settings. This study investigated the effect of various standard filters on the morphology and measurement of extracellular gastric slow waves. Methods Experimental extracellular gastric slow waves were recorded from the serosal surface of the stomach from pigs and humans. Four digital filters: finite impulse response filter (0.05–1 Hz); Savitzky‐Golay filter (0–1.98 Hz); Bessel filter (2–100 Hz); and Butterworth filter (5–100 Hz); were applied on extracellular gastric slow wave signals to compare the changes temporally (morphology of the signal) and spectrally (signals in the frequency domain). Key Results The extracellular slow wave activity is represented in the frequency domain by a dominant frequency and its associated harmonics in diminishing power. Optimal filters apply cutoff frequencies consistent with the dominant slow wave frequency (3–5 cpm) and main harmonics (up to ∼2 Hz). Applying filters with cutoff frequencies above or below the dominant and harmonic frequencies was found to distort or eliminate slow wave signal content. Conclusions & Inferences Investigators must be cognizant of these optimal filtering practices when detecting, analyzing, and interpreting extracellular slow wave recordings. The use of frequency domain analysis is important for identifying the dominant and harmonics of the signal of interest. Capturing the dominant frequency and major harmonics of slow wave is crucial for accurate representation of slow wave activity in the time domain. Standardized filter settings should be determined. … (more)
- Is Part Of:
- Neurogastroenterology & motility. Volume 25:Issue 1(2013:Jan.)
- Journal:
- Neurogastroenterology & motility
- Issue:
- Volume 25:Issue 1(2013:Jan.)
- Issue Display:
- Volume 25, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2013-0025-0001-0000
- Page Start:
- 79
- Page End:
- 83
- Publication Date:
- 2012-09-13
- Subjects:
- electrogastrography -- gastric dysrhythmia -- gastric electrical activity -- signal processing
Gastrointestinal system -- Motility -- Periodicals
Gastrointestinal system -- Innervation -- Periodicals
616.33 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=nmo ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2982 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/nmo.12012 ↗
- Languages:
- English
- ISSNs:
- 1350-1925
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.371450
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 706.xml