Cryoballoon Versus Radiofrequency for Pulmonary Vein Re‐Isolation After a Failed Initial Ablation Procedure in Patients with Paroxysmal Atrial Fibrillation. (4th December 2012)
- Record Type:
- Journal Article
- Title:
- Cryoballoon Versus Radiofrequency for Pulmonary Vein Re‐Isolation After a Failed Initial Ablation Procedure in Patients with Paroxysmal Atrial Fibrillation. (4th December 2012)
- Main Title:
- Cryoballoon Versus Radiofrequency for Pulmonary Vein Re‐Isolation After a Failed Initial Ablation Procedure in Patients with Paroxysmal Atrial Fibrillation
- Authors:
- POKUSHALOV, EVGENY
ROMANOV, ALEXANDER
ARTYOMENKO, SERGEY
BARANOVA, VERA
LOSIK, DENIS
BAIRAMOVA, SEVDA
KARASKOV, ALEXANDER
MITTAL, SUNEET
STEINBERG, JONATHAN S. - Abstract:
- Abstract : Cryoballoon versus Radiofrequency Ablation . Aim: Catheter ablation of paroxysmal atrial fibrillation (PAF) is associated with an important risk of early and late recurrence, necessitating repeat ablation procedures. The aim of this prospective randomized patient‐blind study was to compare the efficacy and safety of cryoballoon (Cryo) versus radiofrequency (RF) ablation of PAF after failed initial RF ablation procedure. Methods: Patients with a history of symptomatic PAF after a previous failed first RF ablation procedure were eligible for this study. Patients were randomized to Cryo or RF redo ablation. The primary endpoint of the study was recurrence of atrial tachyarrhythmia, including AF and left atrial flutter/tachycardia, after a second ablation procedure at 1 year of follow‐up. All patients were implanted with a cardiac monitor (Reveal XT, Medtronic) to continuously track the cardiac rhythm. Patients with an AF burden (AF%) ≤ 0.5% were considered AF‐free (Responders), while those with an AF% > 0.5% were classified as patients with AF recurrences (non‐Responders). Results: Eighty patients with AF recurrences after a first RF pulmonary vein isolation (PVI) were randomized to Cryo (N = 40) or to RF (N = 40). Electrical potentials were recorded in 77 mapped PVs (1.9 ± 0.8 per patient) in Cryo Group and 72 PVs (1.7 ± 0.8 per patient) in RF Group (P = 0.62), all of which were targeted. In Cryo group, 68 (88%) of the 77 PVs were re‐isolated using only CryoAbstract : Cryoballoon versus Radiofrequency Ablation . Aim: Catheter ablation of paroxysmal atrial fibrillation (PAF) is associated with an important risk of early and late recurrence, necessitating repeat ablation procedures. The aim of this prospective randomized patient‐blind study was to compare the efficacy and safety of cryoballoon (Cryo) versus radiofrequency (RF) ablation of PAF after failed initial RF ablation procedure. Methods: Patients with a history of symptomatic PAF after a previous failed first RF ablation procedure were eligible for this study. Patients were randomized to Cryo or RF redo ablation. The primary endpoint of the study was recurrence of atrial tachyarrhythmia, including AF and left atrial flutter/tachycardia, after a second ablation procedure at 1 year of follow‐up. All patients were implanted with a cardiac monitor (Reveal XT, Medtronic) to continuously track the cardiac rhythm. Patients with an AF burden (AF%) ≤ 0.5% were considered AF‐free (Responders), while those with an AF% > 0.5% were classified as patients with AF recurrences (non‐Responders). Results: Eighty patients with AF recurrences after a first RF pulmonary vein isolation (PVI) were randomized to Cryo (N = 40) or to RF (N = 40). Electrical potentials were recorded in 77 mapped PVs (1.9 ± 0.8 per patient) in Cryo Group and 72 PVs (1.7 ± 0.8 per patient) in RF Group (P = 0.62), all of which were targeted. In Cryo group, 68 (88%) of the 77 PVs were re‐isolated using only Cryo technique; the remaining 9 PVs were re‐isolated using RF. In RF group, all 72 PVs were successfully re‐isolated (P = 0.003 vs Cryo). By intention‐to‐treat, 23 (58%) RF patients were AF‐free vs 17 (43%) Cryo patients on no antiarrhythmic drugs at 1 year (P = 0.06). Three patients had temporary phrenic nerve paralysis in the Cryo group; the RF group had no complications. Of the 29 patients who had only Cryo PVI without any RF ablation, 11 (38%) were AF‐free vs 20 (59%) of the 34 patients who had RF only (P = 0.021). Conclusion: When patients require a redo pulmonary vein isolation ablation procedure for recurrent PAF, RF appears to be the preferred energy source relative to Cryo. (J Cardiovasc Electrophysiol, Vol. 24, pp. 274‐279, March 2013) … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 24:Number 3(2013:Mar.)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 24:Number 3(2013:Mar.)
- Issue Display:
- Volume 24, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 24
- Issue:
- 3
- Issue Sort Value:
- 2013-0024-0003-0000
- Page Start:
- 274
- Page End:
- 279
- Publication Date:
- 2012-12-04
- Subjects:
- atrial fibrillation -- catheter ablation -- cryoballoon ablation -- implantable loop recorder -- pulmonary vein isolation
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.12038 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2708.xml