Accuracy of an automated transthoracic echocardiographic tool for 3D assessment of left heart chamber volumes. Issue 2 (February 2017)
- Record Type:
- Journal Article
- Title:
- Accuracy of an automated transthoracic echocardiographic tool for 3D assessment of left heart chamber volumes. Issue 2 (February 2017)
- Main Title:
- Accuracy of an automated transthoracic echocardiographic tool for 3D assessment of left heart chamber volumes
- Authors:
- Spitzer, Ernest
Ren, Ben
Soliman, Osama I. I.
Zijlstra, Felix
Van Mieghem, Nicolas M.
Geleijnse, Marcel L. - Abstract:
- Abstract : Aims: The feasibility and accuracy of an automated adaptive algorithm (Heart Model) for the quantification of left heart chamber volumes and left ventricular ejection fraction has been reported earlier. An improved version of the algorithm is available, and we aimed to test its accuracy compared with manual 3D echocardiography. Methods and Results: Apical 3D transthoracic datasets were obtained in 67 patients. Acquisitions covering ventricles and atria were performed for analysis using the automated software (Heart Model, Philips Healthcare). In addition, acquisitions focused on the left ventricle were acquired for left ventricle manual 3D measurements (QLAB 10 3DQA, Philips Healthcare). Automated results using endocardial contouring settings at 50% showed a strong correlation with manual 3D measurements ( r =.84‐.97). Left ventricular end‐diastolic volumes were underestimated (bias −5.9 mL, LOA ±38.5 mL), with no significant differences in other parameters. Intra‐observer variability using the automated algorithm was zero for all parameters given the lack of human interaction. Manual corrections of the automatic algorithm introduced small but significant differences in volumes but not in ejection fraction when compared with automatic results. Manually corrected results of the automatic algorithm were not significantly different from those obtained with manual 3D echocardiography, except for a small underestimation of left atrial volumes (bias −2.1 mL, LOAAbstract : Aims: The feasibility and accuracy of an automated adaptive algorithm (Heart Model) for the quantification of left heart chamber volumes and left ventricular ejection fraction has been reported earlier. An improved version of the algorithm is available, and we aimed to test its accuracy compared with manual 3D echocardiography. Methods and Results: Apical 3D transthoracic datasets were obtained in 67 patients. Acquisitions covering ventricles and atria were performed for analysis using the automated software (Heart Model, Philips Healthcare). In addition, acquisitions focused on the left ventricle were acquired for left ventricle manual 3D measurements (QLAB 10 3DQA, Philips Healthcare). Automated results using endocardial contouring settings at 50% showed a strong correlation with manual 3D measurements ( r =.84‐.97). Left ventricular end‐diastolic volumes were underestimated (bias −5.9 mL, LOA ±38.5 mL), with no significant differences in other parameters. Intra‐observer variability using the automated algorithm was zero for all parameters given the lack of human interaction. Manual corrections of the automatic algorithm introduced small but significant differences in volumes but not in ejection fraction when compared with automatic results. Manually corrected results of the automatic algorithm were not significantly different from those obtained with manual 3D echocardiography, except for a small underestimation of left atrial volumes (bias −2.1 mL, LOA ±15.2 mL). Conclusions: The current improved version of the automated adaptive algorithm is accurate for the assessment of left heart chamber volumes, albeit a small underestimation of left ventricular end‐diastolic volume is seen, when compared with manual 3D echocardiography. … (more)
- Is Part Of:
- Echocardiography. Volume 34:Issue 2(2017)
- Journal:
- Echocardiography
- Issue:
- Volume 34:Issue 2(2017)
- Issue Display:
- Volume 34, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 34
- Issue:
- 2
- Issue Sort Value:
- 2017-0034-0002-0000
- Page Start:
- 199
- Page End:
- 209
- Publication Date:
- 2017-02
- Subjects:
- left atrial volume -- left ventricular ejection fraction -- left ventricular volume -- three‐dimensional echocardiography
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.13436 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2232.xml