Frequency-domain active contours solution to evaluate intima–media thickness of the common carotid artery. (February 2015)
- Record Type:
- Journal Article
- Title:
- Frequency-domain active contours solution to evaluate intima–media thickness of the common carotid artery. (February 2015)
- Main Title:
- Frequency-domain active contours solution to evaluate intima–media thickness of the common carotid artery
- Authors:
- Bastida-Jumilla, M.C.
Menchón-Lara, R.M.
Morales-Sánchez, J.
Verdú-Monedero, R.
Larrey-Ruiz, J.
Sancho-Gómez, J.L. - Abstract:
- Highlights: Fully-automatic segmentation of the intima-media complex (IMC) and the near wall. Automatic validation stage discards unreliable measurements from a medical point of view. Frequency-implementation of the active contours speeds up the algorithm. Softer contours than other fully-automatic methods. Tested in a wide range of spatial resolutions (from 0.029 mm/pixel to 0.081 mm/pixel). Abstract: The intima–media thickness (IMT) of the common carotid artery (CCA) is being used as a reliable and early detector of atherosclerosis. Atherosclerosis may be unnoticed fo years before triggering severe illnesses such as stroke, embolisms or ischemia. Hence, the use of IMT leads to an early atherosclerosis diagnosis that can prevent more serious cardiovascular diseases. Usually, IMT is manually extracted from ultrasound images, which is a non-invasive technique, but unfortunately its measurement is prone to error. This paper addresses a fully automatic method to segment the artery layers of the CCA over ultrasound images. Unlike other methods, the segmentation is not restricted to IMT, the artery diameter can be extracted too, which can help to determine cardiovascular risk together with IMT. The proposed technique is based on a frequency-domain implementation of active contours, which are computationally faster than the original space-formulation, while providing soft final contours. Working with three different probes over a range of spatial resolutions from 0.029 mm/pixel toHighlights: Fully-automatic segmentation of the intima-media complex (IMC) and the near wall. Automatic validation stage discards unreliable measurements from a medical point of view. Frequency-implementation of the active contours speeds up the algorithm. Softer contours than other fully-automatic methods. Tested in a wide range of spatial resolutions (from 0.029 mm/pixel to 0.081 mm/pixel). Abstract: The intima–media thickness (IMT) of the common carotid artery (CCA) is being used as a reliable and early detector of atherosclerosis. Atherosclerosis may be unnoticed fo years before triggering severe illnesses such as stroke, embolisms or ischemia. Hence, the use of IMT leads to an early atherosclerosis diagnosis that can prevent more serious cardiovascular diseases. Usually, IMT is manually extracted from ultrasound images, which is a non-invasive technique, but unfortunately its measurement is prone to error. This paper addresses a fully automatic method to segment the artery layers of the CCA over ultrasound images. Unlike other methods, the segmentation is not restricted to IMT, the artery diameter can be extracted too, which can help to determine cardiovascular risk together with IMT. The proposed technique is based on a frequency-domain implementation of active contours, which are computationally faster than the original space-formulation, while providing soft final contours. Working with three different probes over a range of spatial resolutions from 0.029 mm/pixel to 0.081 mm/pixel, the method presents an IMT error of only 13.8 ± 31.9 μm (in mean ± standard deviation) when tested on an database containing 46 images. The automatic results were compared to the average of 2 manual observations performed by 2 observers (4 observations) over each image in our database. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 16(2015)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 16(2015)
- Issue Display:
- Volume 16, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 2015
- Issue Sort Value:
- 2015-0016-2015-0000
- Page Start:
- 68
- Page End:
- 79
- Publication Date:
- 2015-02
- Subjects:
- Image segmentation -- Active contours -- Ultrasound images -- Intima–media thickness
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2014.08.012 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 86.xml