ECG steganography using curvelet transform. (September 2015)
- Record Type:
- Journal Article
- Title:
- ECG steganography using curvelet transform. (September 2015)
- Main Title:
- ECG steganography using curvelet transform
- Authors:
- Edward Jero, S.
Ramu, Palaniappan
Ramakrishnan, S. - Abstract:
- Highlights: An attempt is made to hide patient data in ECG signals using steganography. Curvelet transform permit identifying characteristic points of the ECG signal. Modifying coefficients around zero is most favorable. An adaptive n × n sequence scheme is proposed to identify the watermark location. Diagnosability is preserved while achieving imperceptibility and reliability. Abstract: ECG steganography allows secured transmission of patient data that are tagged to the ECG signals. Signal deterioration leading to loss of diagnosis information and inability to retrieve patient data fully are the major challenges with ECG steganography. In this work, an attempt has been made to use curvelet transforms which permit identifying the coefficients that store the crucial information about diagnosis. The novelty of the proposed approach is the usage of curvelet transform for ECG steganography, adaptive selection of watermark location and a new threshold selection algorithm. It is observed that when coefficients around zero are modified to embed the watermark, the signal deterioration is the least. In order to avoid overlap of watermark, an n × n sequence is used to embed the watermark. The imperceptibility of the watermark is measured using metrics such as Peak Signal to Noise Ratio, Percentage Residual Difference and Kullback-Leibler distance. The ability to extract the patient data is measured by the Bit Error Rate. Performance of the proposed approach is demonstrated on theHighlights: An attempt is made to hide patient data in ECG signals using steganography. Curvelet transform permit identifying characteristic points of the ECG signal. Modifying coefficients around zero is most favorable. An adaptive n × n sequence scheme is proposed to identify the watermark location. Diagnosability is preserved while achieving imperceptibility and reliability. Abstract: ECG steganography allows secured transmission of patient data that are tagged to the ECG signals. Signal deterioration leading to loss of diagnosis information and inability to retrieve patient data fully are the major challenges with ECG steganography. In this work, an attempt has been made to use curvelet transforms which permit identifying the coefficients that store the crucial information about diagnosis. The novelty of the proposed approach is the usage of curvelet transform for ECG steganography, adaptive selection of watermark location and a new threshold selection algorithm. It is observed that when coefficients around zero are modified to embed the watermark, the signal deterioration is the least. In order to avoid overlap of watermark, an n × n sequence is used to embed the watermark. The imperceptibility of the watermark is measured using metrics such as Peak Signal to Noise Ratio, Percentage Residual Difference and Kullback-Leibler distance. The ability to extract the patient data is measured by the Bit Error Rate. Performance of the proposed approach is demonstrated on the MIT-BIH database and the results validate that coefficients around zero are ideal for watermarking to minimize deterioration and there is no loss in the data retrieved. For an increased patient data size, the cover signal deteriorates but the Bit Error Rate is zero. Therefore the proposed approach does not affect diagnosability and allows reliable steganography. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 22(2015)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 22(2015)
- Issue Display:
- Volume 22, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 22
- Issue:
- 2015
- Issue Sort Value:
- 2015-0022-2015-0000
- Page Start:
- 161
- Page End:
- 169
- Publication Date:
- 2015-09
- Subjects:
- ECG steganography -- Adaptive watermarking -- Curvelet coefficients -- Quantization -- n × n Sequence method
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2015.07.004 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1836.xml