Diffusion MRI in the heart. (20th October 2015)
- Record Type:
- Journal Article
- Title:
- Diffusion MRI in the heart. (20th October 2015)
- Main Title:
- Diffusion MRI in the heart
- Authors:
- Mekkaoui, Choukri
Reese, Timothy G.
Jackowski, Marcel P.
Bhat, Himanshu
Sosnovik, David E. - Other Names:
- Vermathen Peter guestEditor.
- Abstract:
- Abstract : Diffusion MRI provides unique information on the structure, organization, and integrity of the myocardium without the need for exogenous contrast agents. Diffusion MRI in the heart, however, has proven technically challenging because of the intrinsic non‐rigid deformation during the cardiac cycle, displacement of the myocardium due to respiratory motion, signal inhomogeneity within the thorax, and short transverse relaxation times. Recently developed accelerated diffusion‐weighted MR acquisition sequences combined with advanced post‐processing techniques have improved the accuracy and efficiency of diffusion MRI in the myocardium. In this review, we describe the solutions and approaches that have been developed to enable diffusion MRI of the heart in vivo, including a dual‐gated stimulated echo approach, a velocity‐ ( M 1 ) or an acceleration‐ ( M 2 ) compensated pulsed gradient spin echo approach, and the use of principal component analysis filtering. The structure of the myocardium and the application of these techniques in ischemic heart disease are also briefly reviewed. The advent of clinical MR systems with stronger gradients will likely facilitate the translation of cardiac diffusion MRI into clinical use. The addition of diffusion MRI to the well‐established set of cardiovascular imaging techniques should lead to new and complementary approaches for the diagnosis and evaluation of patients with heart disease. © 2015 The Authors. NMR in BiomedicineAbstract : Diffusion MRI provides unique information on the structure, organization, and integrity of the myocardium without the need for exogenous contrast agents. Diffusion MRI in the heart, however, has proven technically challenging because of the intrinsic non‐rigid deformation during the cardiac cycle, displacement of the myocardium due to respiratory motion, signal inhomogeneity within the thorax, and short transverse relaxation times. Recently developed accelerated diffusion‐weighted MR acquisition sequences combined with advanced post‐processing techniques have improved the accuracy and efficiency of diffusion MRI in the myocardium. In this review, we describe the solutions and approaches that have been developed to enable diffusion MRI of the heart in vivo, including a dual‐gated stimulated echo approach, a velocity‐ ( M 1 ) or an acceleration‐ ( M 2 ) compensated pulsed gradient spin echo approach, and the use of principal component analysis filtering. The structure of the myocardium and the application of these techniques in ischemic heart disease are also briefly reviewed. The advent of clinical MR systems with stronger gradients will likely facilitate the translation of cardiac diffusion MRI into clinical use. The addition of diffusion MRI to the well‐established set of cardiovascular imaging techniques should lead to new and complementary approaches for the diagnosis and evaluation of patients with heart disease. © 2015 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd. Abstract : Diffusion MRI provides unique information on the integrity of the myocardium without the need for exogenous contrast agents. However, diffusion MRI in the heart has proven technically challenging. In this review, we describe approaches that have been developed to overcome these challenges, and briefly examine the application of diffusion MRI in ischemic heart disease. The use of diffusion MRI as a clinical tool may lead to new and complementary approaches to diagnose and treat patients with heart disease. … (more)
- Is Part Of:
- NMR in biomedicine. Volume 30:Number 3(2017:Mar.)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 30:Number 3(2017:Mar.)
- Issue Display:
- Volume 30, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2017-0030-0003-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2015-10-20
- Subjects:
- MRI -- diffusion -- tensor -- tractography -- heart -- myocardium -- myofiber architecture -- ischemia
Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.3426 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2008.xml