Free breathing three‐dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators. Issue 4 (28th April 2016)
- Record Type:
- Journal Article
- Title:
- Free breathing three‐dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators. Issue 4 (28th April 2016)
- Main Title:
- Free breathing three‐dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators
- Authors:
- Menon, Rajiv G.
Miller, G. Wilson
Jeudy, Jean
Rajagopalan, Sanjay
Shin, Taehoon - Abstract:
- Abstract : Purpose: To develop a three‐dimensional, free‐breathing, late gadolinium enhancement (3D FB‐LGE) cardiovascular magnetic resonance (CMR) technique, and to compare it with clinically used two‐dimensional breath‐hold LGE (2D BH‐LGE). Methods: The proposed 3D FB‐LGE method consisted of inversion preparation, inversion delay, fat saturation, outer volume suppression, one‐dimensional projection navigators, and a segmented stack of spirals acquisition. The 3D FB‐LGE and 2D BH‐LGE scans were performed on 29 cardiac patients. Qualitative analysis and quantitative analysis (in patients with scar) were performed. Results: No significant differences were noted between the 3D FB‐LGE and 2D BH‐LGE data sets in terms of overall image quality score (2D: 4.69 ± 0.60 versus 3D: 4.55 ± 0.51, P = 0.46) and image artifact score (2D: 1.10 ± 0.31 versus 3D: 1.17 ± 0.38; P = 0.63). The average difference in fractional scar volume between the 3D and 2D methods was 1.9% (n = 5). Acquisition time was significantly shorter for the 3D FB‐LGE over 2D BH‐LGE by a factor of 2.83 ± 0.77 ( P < 0.0001). Conclusions: The 3D FB‐LGE is a viable option for patients, particularly in acute settings or in patients who are unable to comply with breath‐hold instructions. Magn Reson Med 77:1533–1543, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- Is Part Of:
- Magnetic resonance in medicine. Volume 77:Issue 4(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 77:Issue 4(2017)
- Issue Display:
- Volume 77, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 4
- Issue Sort Value:
- 2017-0077-0004-0000
- Page Start:
- 1533
- Page End:
- 1543
- Publication Date:
- 2016-04-28
- Subjects:
- 3D late gadolinium enhancement (LGE) -- stack‐of‐spirals imaging -- motion correction -- outer volume suppression -- free‐breathing -- cardiovascular magnetic resonance
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26234 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1626.xml